I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
 ;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
 ;
It is OK, this manual help me to repair my dynacord
 ;
Good manual. Even it is an old printed manual, it is well scanned and complete, with all drawings, schematics and parts list. Very good return for the cost.
 ;
I'm very satisfied with my purchase. It resolved my problem. Owner-manuals.com is a very very good place.
Thank you!
August 2nd, 1995
TROUBLESHOOTING COPY QUALITY TROUBLESHOOTING
6.1.8. Horizontal White Lines
H516T509.wmf
H516T511.wmf
Possible Cause (Printer) � The surface of the development roller is damaged or deformed. � The development bias is not stable. � Transfer current is not stable. Action: 1. Print a test pattern, and open the cover in the middle of printing. 2. Check if horizontal white lines (where toner is not adhered) appear on the drum surface or not. � If they do, go to step 3. � If not, check the transfer roller surface and the transfer bias terminals connections. If they are OK, check or replace the power pack. 3. Check if horizontal white lines (where toner is not adhered) appear on the development roller surface or not. � If they do, check if the development roller surface is not deformed. If it is OK, check or replace the power pack. � If not, check for damage on the drum surface.