|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
INC
FSA03301-R.3564.A
� There are high voltege parts inside. Be careful of this electric shock, when you remove the cover. � Do not attach the screw longer than M1.7 x 5.5 to the hole for measurement of main condenser voltage because there is high voltage part inside.
� Confirmation of the main condenser voltage: Standard value: 330 ± 10V � It is possible to measure voltage by inserting a thin probe in the hole for measurement of the main condenser. (Hole for measurement - GND) � � For safety, be careful of high voltage. The following calculation is needed. � Main condenser voltage = Meaured value x (1 + 470k Ω / Input impedance of the meter) e.g.: When an input impedance of the meter (resistance) is 10M Ω and a measured value is 315V, 315�1.047 = apporox. 330V. * Input impedance of the meter (resistance) is indicated on the bottom face of the meter or in the instruction manual. � Confirmation of the safety circuit operation voltage: Standard value: The safety circuit operates at between 341V � 360V and this SB fires fully. It is possible to confirm the operation voltage of the safety circuit by oscillating with the MO terminal connected with the GND so that oscillation does not stop even the main condenser voltage reaches 330V. After the adjustment, attach the screw to the hole for measurement of the main condenser voltage. � Adjustment of the flash output level for non-TTL auto flash: Standard value : ±1EV at every position of the followings Rotate the VR1 slowly so that the value would be F5.6 at the F5.6 position. After the adjustment, confirm it at the other positions (F2.8, F4, F8) and they should satisfy the standard.
Standard reflector 2m
Flash meter
�
Adjustment of the manual auto flash level: Standard value : M1/1=GN16±0.5EV � �M1/8=GN5.6±0.5EV � �M1/32=GN2.8±0.5EV Rotate the VR2 slowly so that would be GN=5.6 at the position of M1/8. After the adjustment, confirm the value at another position (M1/32) and it should satisfy the standard. - A2 ・ SB-30 -
|
|
 |
> |
|