July 1, �85
6D-8. By-pass Feed Table Removal 1. Open the front cover and remove the front inner cover (4 screws). [FT3020] Open the front cover, push the slide unit to the left, and remove the inner cover (5 screws). [FT3050/FT3060] Remove the E-ring from the front shaft of the by-pass feed table. Remove the right rear cover (2 screws) Open the by-pass feed table and remove the inner cover and the toner tank cover (2 screws). Remove the rear cover (2 screws) and the main PCB (2 screws, 4 connectors). [FT3020] Remove the rear cover (2 screws) and the optics PCB (1 screw, 4 connectors). [FT3050/FT3060] Remove the stud screw from the rear side. Take off the by-pass feed table. [FT3020] (1 connector, 1 bushing) [FT3050/FT3060]
CAUTION: When reinstalling, do not damage the cassette arm release lever nor the bypass feed table sensor.
2.
3. 4.
5.
6. 7.
6-39
|
|
 |
> |
|