|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was very glad recieving the service manal from You. Additionaly very fast. Extremaly nice servicing. Thanks very mach! Now my GX-220 working better, than it was made. Alexander from Moscow, Russia/
 ;
Sweet! I won the item on eBay and couldn't adjust the geometry or even keep a steady picure. This guide has the full schematics (not available anywhere else as far as I could tell), and was a bargain for the wealth of knowledge it contains. I hooked it up to my testing equipment, tweaked a few potentiometers and got it playing videogames in no time. Thanks!
 ;
It was just what I need to fix my old BMW's CD player. Very convenient also. Thank you.
 ;
Great Manual! It contains all the wiring schematics and mechanical exploded views that are essential for service and repair. I was surprised I even found this for such an old machine. Only wish I knew of this site many years ago.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
16 April �88
SERVICE REMARKS
1. Handling the Drum
1.
Never touch the drum surface with bare hands. Store the drum in a cool dry place. Always wear gloves when cleaning the drum. Only prime the drum with setting powder when installing new drum. Never expose the drum to light for a long time. Drum conditioning is necessary when a new drum is installed. In addition, it is useful at the following times: . When image density is reduced due to over-exposure of the drum. q After cleaning the drum.
2. 3. 4. 5. 6.
7.
Always keep the drum in the protective sleeve when inserting or pulling the drum out of the copier.
8 * Before inserting or pulling out the drum, the cleaning unit should be pulled slightly out to avoid drum damage by the pick-off pawls. 9. Return used drums to the distributor according to standard procedure.
2. Charge Corona
1.
Clean the corona wires with a dry cloth or by sliding the corona unit in and out. Do not use emery paper or any solvent for wire cleaning. Do not touch the corona wires with oily hands. Oil stains may cause white bands on copies. Make sure that the corona wires are correctly positioned between the cleaner pads and there are no threads on the casing. When adjusting the drum current, always make sure that the axis of drum shoe is aligned with the corona wire. The corona wire height should be adjusted only when: a) The front end block is replaced. b) The drum charge current is uneven.
2. 3. 4. 5.
4-14
|
|
 |
> |
|