Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
 ;
High quality scan of original Service Manual. Everything´s fine!
 ;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
 ;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
 ;
High quality scan of service manual. I am satisfied!
31 August 1989
5. SERVICE REMARKS
5.1 Handling The Drum 1. Never touch the drum surface with bare hands. 2. Store the drum in a cool dry place. 3. Always wear gloves when cleaning the drum. 4. Prime the drum with setting powder only when the cleaning blade, cleaning brush, and drum are replaced as a set. 5. Never expose the drum to light for a long time. 6. Always keep the drum in the protective sleeve when inserting or pulling the drum out of the copier. 7. Drum conditioning is necessary when a new drum is installed. In addition, it should be done at the following times: a) When image density is reduced due to overexposure of the drum. b) After cleaning the drum. c) When the drum is lightly scratched. 8. Before inserting or sliding out the drum, the cleaning unit should be removed to avoid drum damage. When pulling out the cleaning unit, press the drum shaft slightly to the left. 9. Return used drums to the distributor according to standard procedure. 5.2 Charge Corona 1. Do not use emery paper to clean the corona wire; this abrades the wire coating. 2. Do not touch the corona wire with oily hands. Oil stains may cause white bands on copies. 3. The corona wire height should be adjusted only when a) the front end block is replaced. b) the drum charge current is uneven. 4. Make sure that the corona wires are correctly positioned between the cleaner pads. 5.3 Erase Lamp 1. A narrower lead edge erase margin increases the possibility of fusing jams. The margin should be at least 1.0 mm.
4-19
|
|
 |
> |
|