The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.The schematic is very helpful and the images are very good.
 ;
Welcome. The scheme is clearly helped me to repair. Worth to download it.
Set the handset in the test mode 3, check whether deviation of the TX data is app. 7 kHz Dev. OK
NG
Check whether there is a 250Hz data waveform at Pin 9 of J601. OK
NG
Check VR601, R619, R632, R634, R635, R636 and C611.
Check handset RF unit.
Set the handset in the test mode 6, 927.000602 MHz (250 Hz ±7 kHz Dev.) 1mV output signal from RF jack is applied. Check whether the bell ring. OK Place the handset on the base to charge about 5 seconds, then connect again.
NG
Check whether the 250 Hz data wareform from Pin 1 of J601 is fed. OK Check whether there is a 250 Hz data waveform at the Q601 collector. OK
NG Check handset RF unit.
NG
Check VR602, Q601 and their peripheral circuits.
Check whether there is a 250 Hz data waveform at Pin 55 of IC603. OK Check IC603 and its peripheral circuit.
NG
Check Q602, Q604 and their peripheral circuits.