Service hints CAUTION
10-2
CHARGED CAPACITORS ON THE SERVO BOARD MAY DAMAGE THE CD DRIVE ELECTRONICS WHEN CONNECTING A NEW CD MECHANISM. THAT´S WHY, BESIDES THE SAFETY MEASURES LIKE � SWITCH OFF POWER SUPPLY � ESD PROTECTION ADDITIONAL ACTIONS MUST BE TAKEN BY THE REPAIR TECHNICIAN.
The following steps have to be done when replacing the CD mechanism: 1. Disconnect flexfoil cable from the old CD drive 2. Put a paperclip onto the flexfoil cable to short-circuit the contacts (fig.1) 3. Remove the old CD drive 4. Remove paperclip from the flexfoil cable and connect it to the new CD drive 5. Position the new CD drive on its studs 6. Remove solder joint from the Laser unit (see below)
fig.1
Attention: The laser diode of this CD drive is protected against ESD by a solder joint which short-circuits the laserdiode to ground. For proper functionality of the CD drive this solder joint must be removed after connecting the drive to the set.
Emergency open