Very good service Within one day i received a pdf of the users manual and electric circuits so I was able to measure the different voltages in the printed circuit and find out the fault Payment was also reliable and easy.Without the manual i could not have repaired.So thanks to "Search for a manual"
 ;
you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
 ;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
 ;
Item as described, very well detailed manual with complete schematics. I've received the download information shortly after payment, very good support.
 ;
Really good and well scanned. File is complete the full service manual for 5$
Service hints CAUTION
10-2
CHARGED CAPACITORS ON THE SERVO BOARD MAY DAMAGE THE CD DRIVE ELECTRONICS WHEN CONNECTING A NEW CD MECHANISM. THAT´S WHY, BESIDES THE SAFETY MEASURES LIKE � SWITCH OFF POWER SUPPLY � ESD PROTECTION ADDITIONAL ACTIONS MUST BE TAKEN BY THE REPAIR TECHNICIAN.
The following steps have to be done when replacing the CD mechanism: 1. Disconnect flexfoil cable from the old CD drive 2. Put a paperclip onto the flexfoil cable to short-circuit the contacts (fig.1) 3. Remove the old CD drive 4. Remove paperclip from the flexfoil cable and connect it to the new CD drive 5. Position the new CD drive on its studs 6. Remove solder joint from the Laser unit (see below)
fig.1
Attention: The laser diode of this CD drive is protected against ESD by a solder joint which short-circuits the laserdiode to ground. For proper functionality of the CD drive this solder joint must be removed after connecting the drive to the set.
Emergency open