|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
MACKIE HR824 26 pages English-only Service Manual contains:
1) HR824 technical overview with the description of front and rear panel switches.
2) HR824 specs
3) Block Diagram
4) Wiring Diagram
5) Packaging management
6) Spare part & final assembly list (for PCB rev A and B) + exploded view
7) Test Procedures (where, how to measure voltage...) including Test Point diagram on the PCB.
8) IC and Transistor charts.
Excellent guide: very clear, good scan quality enabling us to print readable diagram :-)
Note:
Mackie HR824 make extensive use of surface mount devices (SMD). Service on the HR824 must
only be undertaken by experienced service technicians with the right tools, experience and patience to perform surface mount rework when needed.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
 ;
The service was great and the document was also great. Highly recommend!!!!
If anyone has a users manual... Please email me. need one. $ [email protected]
 ;
I needed a service manual as the display on my oscilloscope was very dim. I thought I'd give owner-manuals.com a try, as they advertised a huge number of manuals. Sure enough they had one listed. I bought it hoping it would be useful... actually, I bought it hoping it would be readable! I've had manuals from online sources in the past, and been very disappointed. Not this time! An excellent manual, complete, and very readable. Using it I fixed my 'scope, and as such the manual was an investment that paid off manyfold. Do I have any complaints? One very minor one - The circuit diagrams could have been scanned at a higher resolution, as some of the details were a little difficult to make out - not impossible, just not as easy as my old eyes would like! Overall, I'm very satisfied with my manual, and I will certainly be using this company again. Well done.
SAFETY INSTRUCTION
CAUTION
WARNING : BEFORE SERVICING THIS CHASSIS,READ THE �X-RAY RADIATION PRECAUTION�, � SAFETY PRECAUTION� AND �PRODUCTION SAFETY NOTICE� BELOW. X-RAY RADIATION PRECAUTION
1. Excessive high voltage can produce potentially hazard ous X-RAY RADIATION. To avoid such hazards, the high voltage must not exceed the specified limit The nominal value of the highvoltage of this receiver is 23-25KV(14�),25-28KV(20�),25~29KV(21�) at max. beam current, The high voltage must not,under any circumstances, exceed 26KV(14�),30KV(20�),31KV(21�). Each time a receiver requires servicing,the high voltage should be checked. It is recommended the reading of the high voltage be recorded as a part of the service records, It is important to use an accurate and reliable high voltage meter. 2. The only source of X-RAY radiation in this TV receiver is the picture tube. For continuous X-RAY RADIATION protection, the replacemnt tube must be exactly the same type tube as specified in the parts list.
PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in this have special safety-related characteristics. These characteristics are often passed unnoticed by a visual inspection and the X-RAY RADIATION protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage,etc. Replacement parts which have these special safety characteristics are identified in this manual and its supplements, electrical components having such features are identified by designated symbol on the parts list. Before replacing any of these components,read the parts list in this manual carefully. The use of substitute replacement parts which do not have the same safety characteristics as specified in the parts list may create X-RAY Radiation.
SAFETY PRECAUTION
1. Potentials of high voltage are present when this receiver is operating. Operation of the receiver outside the cabinet or with the back board removed involves a shock hazard from the receiver. 1) Servicing should not be attempted by anyone who is not thoroughly familiar with the precautions necesary when working on high voltage equipment. 2) Always discharge the picture tube before handling the tube.The picture tube is highly evacuated and if briken, glass fragments will be violently expelled. 2. If any fuse in this TV receiveris blown, replace it with the FUSE specified in the Replacement Parts list. 3. When replacing a high wattage resistor ( metal oxide film resistor ) in circuit board, keep the resistor 10mm away from circuit board. 4. Keep wires away from high voltage or high temperature components. 5. This receiver must operate under AC260 volts, 50Hz. NEVER connect to DC supply or any other power or frequency.
2
|
|
 |
> |
|