|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
GEX-P900XM
Description Specified Primary and Secondary PCID do not exist in an identical ensemble. The PC signal of the specified program cannot be received. SID of the specified program cannot be verified. The service component type of the specified program cannot be verified. Updating the encryption key. Have not signed up for the charge service contract. A program has been selected that is outside the range of the charge contract. The time information, managed inside the DSP core and the time information aired, do not match. FF REQ_RETRY Failure occurred with the SSDEC (a restart is requested). Display example: If the system is receiving, the display will momentarily show [M2_00_20]. 4.12 ANTENNA PASS No display. If an antenna is not connected, and if this setting is made while the system is displaying the "ANTENNA" message, connection checks will not be conducted until the system has been reset (the system will assume normal operation without an antenna check). 4.13 QOS Message Display format: [1AABBCCD]. A: The Bitabi error rate (two effective digits of decimal value) of terrestrial wave*1. B: The Bitabi error rate (two effective digits of decimal value) of satellite wave 1*1. C: The Bitabi error rate (two effective digits of decimal value) of terrestrial wave 2*1. D: The quality of service (QOS) value (a single effective digit decimal value)*2. *1: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will show "-". For 100, the display will show "XX". If a signal is not received, the display will show "NS." *2: The single digit display may show from 0 to 9. If the display information is being acquired, the display will show "-". For 10 and over, the display will show "X". 4.14 TERR Message Display format: [2ABBCCDD] A: The locking status of the terrestrial wave*1. B: The terrestrial wave Bitabi signal error rate (two effective digits of decimal value)*2. C: The terrestrial wave Read-Solomon symbol error rate (two-effective digits of decimal value)*3. D: The terrestrial wave Read-Solomon non-correction code word (two effective digits of decimal value)*4. *1: The "-" will be displayed while the system is acquiring the information, "N" if the signal is not locked on, "D" if only the demodulator is locked, and "T" if both the TDM and demodulator are locked on. *2: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will show "-". For 100, the display will show "XX". If a signal is not received, the display will show "NS." *3: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will show "-". For 100, the display will show "XX". *4: The two-digit display may show from 0 to 99. If the display information is being acquired, the display will show "-". For 100, the display will show "XX".
Mode number ED EE EF F0 F1 F3 F4 F5
Mode name DIFF_ENS PC_UNDETECT SID_UNDETECT SCT_UNDETECT AUTH_MISS RAT_BLOCK RAT_LOW TOD_ROLLBACK
44
|
|
 |
> |
|