Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
 ;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
 ;
High quality scan of service manual. I am satisfied!
 ;
Excellent copies.
I will use "Owner Manual" again a second time.
5 Troubleshooting
CONFIDENTIAL
5-2 No Video
Check signal cable connection and power.
Does the X201 and X202 oscillate properly?
1 2
No
Replace that or check related circuit.
Yes There R, G, B input are at R103, R104 and R105? Yes There sync. and data output are R212, R213, R214, R215, and RA201 ~ RA212?
3 4 5 6
No
Check input part.
No
Please check the power related IC201 and output part.
Yes There proper signal input are Pin 27, 28, 30, and 31 of IC301, IC302?
5 3 4 6
No
Check IC301, IC302 and related circuit.
Yes No Does the output signal appear at R304~R323? Yes There are DC 5V at Pin 1, 2 and 3 of CN301? Yes There are DC 12V, DC5V and DC 5V at Pin 10, 11, 12 ; Pin 7 and Pin 4 of CN104? No Please check the Inverter and related circuit. No Check the Power and related circuit. Check the LVDS_EN at R303 is high or not. Normal state is high.
GH17A*/GH17L***J