Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Thanks God for the internet and thanks for the service like this - proffessional solution on time.
 ;
About the service it's very fast and reliable. About the manual the quality is high enough to read even the tiniest details on the wiring diagrams so you can't ask much more than that, let it alone for a manual of a product from 20 years ago. Thank you, very satisfied.
 ;
The downloaded quality was as good as the orignial
 ;
This is a great and complete Service Manual for the Sharp GF8585HB. Giving full and detailed technical insight. Good to find these manuals online.
 ;
Everything was ok with the manual. If I have a small complaint, is that I ordered it during the weekend and I think you guys were closed. But I did receive it late Sunday. I will surely order from you again
GRUNDIG Service
VARIXX UMS 4401 SPCD
Adjustment Procedures
Tuner
Test equipment: Signal Generator, Oscilloscope, Digital Voltmeter Adjustment 1. AM IF Preparation AM, 522kHz; Couple Signal Generator 450kHz via Loop Antenna; Ue > 60dBµV; Oscilloscope to Loudspeaker Output. AM, 1620kHz; Digital Voltmeter to Pin 8 of IC101. AM, 603kHz/1404kHz; Couple Signal Generator via Loop Antenna; Ue > 50dBµV; fmod = 1kHz; Oscilloscope to Loudspeaker Output. Adjustment Procedure Adjust with T105 and T104 for Maximum.
2. AM Oscillator
Adjust with T102 for 7.8V ± 0.2V.
3. AM Band Pass
Adjust alternating with T101 at 603kHz and with T108 at 1404kHz for AF Maximum.
4. AM-AFC
AM, 522kHz; Adjust with T106 for 0V ± 1mV. Couple Signal Generator 450kHz via Loop Antenna; Digital Voltmeter between Pin 19 and Pin 20 of IC101. FM, 87.5MHz; Adjust with T103 for 0V ± 1mV. Signal Generator to FM Aerial Input; Short circuit Pin 21 of U102 to GND; Digital Voltmeter between Pin 19 and Pin 20 of IC101. FM, 87.5MHz; Signal Generator to FM Aerial Input; fmod= 19kHz; Oscilloscope to Loudspeaker Output. Adjust with IFT181 (left channel) and IFT182 (right channel) to Minimum.
5. FM-Det.
6. 19kHz Notch Filter
Tape Deck
Test equipment: Oscilloscope, Frequency Counter, Test Cassette 3150Hz/10kHz (e.g. 448A) Adjustment 1. Tape Speed Preparation Frequency Counter to Loudspeaker Output. Play Test Cassette (3150Hz part). Adjustment Procedure Adjust Motorpoti for 3150Hz ± 10Hz.
Motorpoti
2. Azimuth
Oszilloscope to Loudspeaker Output. Play Test Cassette (10kHz part).
With Head screw A adjust for maximal and equal level in both channels.
A
3. Bias Frequency Frequency Counter to CN105-RR/LR. Start recording.
2-2
Adjust with T201 for 60kHz ± 100Hz.
|
|
 |
> |
|