TH-37PX50U / TH-42PX50U / TH-50PX50U
3. For leaving the plasma panel from the front frame, pull the bottom of the front frame forward, lift, and remove.
6.40. Replace the plasma panel (finished).
1. Place the new plasma panel (finished) on the flat surface of the table (covered by a soft cloth), with the plasma panel surface facing downward. 2. Attach the C1-Board and the C2-Board, connect the flexible cables (�7) from the Plasma panel to the C1-Board and C2Board, and fix the flexible cable holders. 3. Attach the Hooks (left, right) and fit the stand brackets (left, right) to the new plasma panel. 4. Place the plasma panel section on the servicing stand. 5. Attach the front frame and the each P.C.Board and so on, to the new plasma panel. * When fitting the front frame, be careful not to allow any debris, dust or handling residues to remain between the front glass and plasma panel.