El producto satisface las necesidades del servicio t
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
SECTION 5 ELECTRICAL CONFIRMATIONS AND ADJUSTMENTS
DECK SECTION
0 dB=0.775 V 2. Turn the adjustment screw and check output peaks. If the peaks do not match for L-CH and R-CH, turn the adjustment screw so that outputs match within 1dB of peak.
Note: Confirm each contents of this section first of all. If the results are not satisfied, do the adjustment.
1. 2. 3. 4. 5.
Demagnetize the record/playback head with a head demagnetizer. Do not use a magnetized screwdriver for the adjustments. After the adjustments, apply suitable locking compound to the parts adjust. The adjustments should be performed with the rated power supply voltage unless otherwise noted. The adjustments should be performed in the order given in this service manual. (As a general rule, playback circuit adjustment should be completed before performing recording circuit adjustment.) The adjustments should be performed for both L-CH and RCH. Switches and controls should be set as follows unless otherwise specified.
L-CH peak Output level R-CH peak
within 1dB within 1dB
Screw position
6. 7.
L-CH peak
R-CH peak
Screw position
3.
Mode: Playback
test tape P-4-A100 (10 kHz, �10 dB) L-CH MAIN board CN301 set R-CH MAIN board LINE OUT jack (PJ301) L-CH oscilloscope
� Test Tape
Tape P-4-A100 WS-48B P-4-L300 Signal 10 kHz, �10 dB 3 kHz, 0 dB 315 Hz, 0 dB Used for Azimuth Adjustment Tape Speed Adjustment Level Adjustment
V
H
Record/Playback Head Azimuth Adjustment Procedure: 1. Mode: Playback
test tape P-4-A100 (10 kHz, �10 dB) MAIN board LINE OUT jack (PJ301) L-CH, R-CH level meter set + �
R-CH waveform of oscilloscope
in phase 45° good
90° 135° 180° wrong
4. 5.
Repeat step 1 to 3 in playback (REV) mode. After the adjustments, apply suitable locking compound to the pats adjusted.
Adjustment Location:
reverse forward
12
|
|
 |
> |
|