This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
Ver 1.3 2003.01
HCD-DP900D
DVD SECTION
When optical pick-up is exchanged, should make automatic servo adjustment by using the test disk.
Note :
3. Confirm that the S-Y level is 1.0 ± 0.1Vp-p.
1.0 ± 0.1 Vp-p
1. DVD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use HLX-504 (J-6090-088-A) or HLX-505 (J-6090-089-A) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. Video Level Adjustment (MB BOARD) Purpose This adjustment is made to satisfy the NTSC standard, and if not adjusted correctly, the brightness will be too large or small.
4. Connect oscilloscope to S-VIDEO output. (S-C teminal) 5. Connect that the S-C burst is 286 ± 50mVp-p.
286 ± 80 mVp-p
Oscilloscope
75 �
set
Adjustment Location
J601 VIDEO OUTPUT
MB BOARD (SIDE A)
Procedure: 1. Connect oscilloscope to VIDEO output. 2. Load a disc (HLX-504 or HL-505) playback. 3. Adjust the RV501 to attain 1.0±0.1Vp-p.
CN011
1.0 ± 0.1 Vp-p
(WHITE 75%)
S-terminal Output Check Purpose Check S-video output.
RV501 VIDEO LEVEL Adjustment
IC103 IC503
CN008
Oscilloscope
CN404
CN103
set
G G
75 �
J602 S-VIDEO OUTPUT
Procedure: 1. Connect oscilloscope to S-VIDEO out. (S-Y teminal) 2. Load a disc (HLX-504 or HL-505) playback.