Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It was magic after so many years to still be able to source this info. It was equally amazing to return my Pioneer receiver to it near new sound quality AFTER NEARLY 30 YEARS! Thank you for this ability!
 ;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
 ;
Easy and secure way to get a complete service manual of a vintage hifi component. Only some parts of the print copy are dificult to read. Nice price!
 ;
The manual is an excellent reproduction with complete schematics, made troubleshooting and repair a simple process.
 ;
Up to now you are the BEST! Prompt-efficient and so reasonable ! I have been after SONY service manual for quite some time !Thank you very much ! I can recomend your service to
all my collegagues ! V.Bergfield .
HCD-DX150/DX170/DX250
(3) Select �5. MIRR time Adjust�.
Drive Manual Operation
(14) Confirm the same values are displayed. If it is not same, return to step 7.
MIRR time Adjust Menu
1. 2. 3. 4. 5. 0.
Servo Control Track/Layer Jump Manual Adjustment Mecha test mode MIRR time Adjust Return to Top Menu
1. 2. 3. 4. 5.
CD MIRR time Check: DVD MIRR time Check: XX XX Threshold: Save to EEPROM: Default set MIRR time:
(4) Select �5. Default set MIRR time�.
MIRR time Adjust Menu 1. CD MIRR time Check: 2. DVD MIRR time Check: 3. Threshold: 4. Save to EEPROM: 5. Default set MIRR time: [Open] Tray open [Close] Tray close [0] Return to previous menu
[Open] Tray open [close] Tray close [0] Return to previous menu
(15) Push A button to eject tray. (16) Take out HLX-504 and insert Test Disc YEDS-18 into tray. (17) Push A button to close tray. (18) Push �1. CD MIRR time check�. (19) Wait for HEX number to display. (20) Confirm the number, if YY is 5A ~ E8, proceed with next step. If no, return to 15.
MIRR time Adjust Menu 1. 2. 3. 4. 5. CD MIRR time Check: yy YY DVD MIRR time Check: XX XX Threshold: Save to EEPROM: Default set MIRR time:
(5) Select �3. Threshold�. (6) Confirm the number. If it is 75, go to next step. If it is any other value, return to step 4.
MIRR time Adjust Menu 1. 2. 3. 4. 5. CD MIRR time Check: DVD MIRR time Check: Threshold: 75 Save to EEPROM: Default set MIRR time:
[Open] Tray open [Close] Tray close [0] Return to previous menu
[Open] Tray open [close] Tray close [0] Return to previous menu
(7) Push A button to eject tray. (8) Insert Test Disc HLX-504 into tray. (9) Push A button to close tray.
(21) Push �4. Save to EEPROM�. (22) Confirm the same values are displayed. If it is not the same, return to step 15.
MIRR time Adjust Menu
(10) Push �2. DVD MIRR time Check�. (11) Wait for HEX number to display. (12) Confirm the number, if XX is 28 ~ 70, proceed with next step. If no, return to 8.
MIRR time Adjust Menu 1. CD MIRR time Check: 2. DVD MIRR time Check: xx xx 3. Thereshold: 4. Save to EEPROM: 5. Default set MIRR time: [Open] tray open [close] Tray close [0] Return to previous menu
1. 2. 3. 4. 5.
CD MIRR time check: YY YY DVD MIRR time check: XX XX Threshold: Save to EEPROM: Default set MIRR time:
[Open] Tray open [close] Tray close [0] Return to previous menu
(23) Push A button to eject tray. (24) Remove Test Disc YEDS-18 from tray. (25) Push A button to close tray. (26) Press 0 �R� button to the Drive Manual Operation menu. (27) Press 0 �R� button to return to the Remocon Diagnosis Menu. (28) Press the ?/1 button to switch OFF set.
(13) Push �4. Save to EEPROM�.
24
|
|
 |
> |
|