Who's Online
There currently are 5822 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
the manual is in good quality and it's in pdf. manual was send in less then 24h.
regards
mike
;
I would not plug this machine in without finding a manual like this. In addition to setup and normal operating instructions, it has troubleshooting flowcharts, diagrammed mechanical adjustments, and schematics to beat the band. The tech I hand it to would be thrilled to find solder side PCB diagrams with component outlines superimposed, pinouts for every IC chip, and line drawings of transistors, with labeled legs.
As for printing quality, this may be a copy of a copy, but even the finest print when enlarged is very legible. There is a bit of grayed print over a few pages, as if a wet page were placed over it, but the print is still very legible. If you could borrow an original manual and get it printed and bound for 4 to 6 times the cost, you could get better quality. In that case you wouldn't be here. For price, utility, and availability I am rating this manual highly.
;
I received the Manual in a timely manner and it was exactly what I needed.
This is a perfect copy of the Service Manual, The quality is great. I am very
happy. Thank you
;
exactly as they say. Within 24 hours the link to the pages and offcourse it was the right service manual. Super and thanks
;
The manual was exact the thing that was promised. My old car stereo is working again thanks to the information supplied.
3. Mode: Playback
test tape P-4-A100 (10kHz, �10dB) oscilloscope MD OUT
Tape Speed Adjustment (Deck A) Note: Set the test mode using the following method and begin tape speed adjustment. In the test mode, the speed will switch to double speed or normal speed each time the HI-DUB button is pressed. Procedure: With the power turned ON, press the p button, ENTER/NEXT button, and DISC 3 button simultaneously. (The �CD TABLE INDICATOR� on the fluorescent display tube will blink while in the test mode.) To exit the test mode, press the 1/u button.
Waveform of oscilloscope
set
1. Insert the WS-48B into deck B. 2. Press the ( button of deck B. 3. Press the HI-DUB button and play the tape at double speed. 4. Adjust RV1001 of the LEAF SW board so that the reading of the frequency counter becomes 6000 ± 180 Hz. 5. Press the HI-DUB button and play the tape at normal speed. 6. Adjust RV1002 of the LEAF SW board so that the reading of the frequency counter becomes 3000 ± 90 Hz. Adjustment Location: LEAF SW board
in phase
45° good
90°
135°
180° wrong
4. After the adjustments, apply suitable locking compound to the parts adjusted. Adjustment Location: Playback Head (Deck A) Record/Playback/Erase Head (Deck B)
Sample Value of Wow and flutter W.RMS (JIS) less than 0.3% (test tape: WS-48B) Playback Level Adjustment (Deck A, Deck B) Procedure: Mode: Playback
test tape P-4-L300 (315Hz, 0dB) set level meter
Reverse
Foward
MD OUT
Deck A is RV311 (L-CH) and RV411 (R-CH), deck B is RV301 (L-CH) and RV401 (R-CH) so that adjustment within the following adjustment level. Adjustment level: CN301 playback level: 301.5 to 338.3 mV (�8.2 to �7.2 dB) level difference between the channels: within ± 0.5 dB Adjustment Location: AUDIO board
Adjustment Location [LEAF SW BOARD]
RV1001(High Speed) RV1002(Normal Speed)
RV1002
RV1001