Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a high quality manual with clear schematic and components layout diagrams ; with service procedure included.
 ;
This service manual for the Kenwood KT-990D was reproduced really well ,is very legible and manual is complete.Combined with the low price paid,in the future,I will be checking Owner-Manuals.com any time I need a manual.
 ;
When I purchased this manual I had my doubts regarding the quality as the price was so reasonable as compared to other outlets.
The manual itself is of high standard the print is very clear as are the diagrams. Obviously with the diagrams one has to zoom in otherwise it is to small to be able to read.
Overall I am very pleased with the company who delivered as they said and with the manual they supplied.
I occasionally require a manual and now having registered with this company I shall order from them in the future.
 ;
I was at first dubious about payiong for downloaded manuals but having done so, I was extremely impressed with quality of the two manual I ordered, well worth the small price I paid.
I would highly recommend these to my friends.
 ;
reasonable price for the schematic - the service is perfect, all as expected and pointed by instructions - good scan of the original plans - thank you!
CD SECTION
Note: 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10 M� impedance. 4. Clean the object lens by an applicator with lens cleaning liquid when the signal level is low than specified value with the following checks. 5. Adjust the focus bias adjustment when optical block is replaced. Focus Bias Adjustment Perform this adjustment when the optical pick-up has been replaced or repaired.
oscilloscope BD (CD) board TP (RF) TP (VC) + �
S Curve Check
oscilloscope BD (CD) board TP (FEO) TP (VC) + �
Procedure : 1. Connect oscilloscope to test point TP (FEO). 2. Connect between test point TP (FOK) and Ground by lead wire. 3. Turn Power switch on. 4. Put disc (YEDS-18) in and turned Power switch on again and actuate the focus search. (actuate the focus search when disc table is moving in and out.) 5. Check the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 2.4 ± 0.7 Vp-p. S-curve waveform
symmetry
Procedure: 1. Connect oscilloscope to test point TP (RF). 2. Turn Power switch on. 3. Put disc (YEDS-18) in and playback. 4. Adjust RV101 so that the waveform is clear. (Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.) 5. After adjustment, check the RF signal level. � RF signal VOLT/DIV: 200 mV TIME/DIV: 500 nS
A within 2.4 ± 0.7 Vp-p B
6. After check, remove the lead wire connected in step 2.
Note: � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform.
RF Level Check
oscilloscope
level : 1.3 ± 0.3 Vp-p
BD (CD) board TP (RF) TP (VC) + �
Procedure : 1. Connect oscilloscope to test point TP (RF) on BD (CD) board. 2. Turn Power switch on. 3. Put disc (YEDS-18) in and playback. 4. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not.
Note: Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.
RF signal waveform
VOLT/DIV : 200 mV TIME/DIV : 500 nS
level : 1.3 ± 0.3 Vp-p
� 31 �
|
|
 |
> |
|