Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I work at an authorized service center and I can tell if a manual is as it should be. This one is. It may be a scan, but a very good one at that. The interesting part for me was the curcuit diagram which was scanned at high quality, making it as good as the original. I will definitely be back as a customer. I need not say this, but I will: the price was the best. Thank you owner-manuals.com .
 ;
really a very good manual even sometimes the quality is no so good as before still very readible and very very useful!
 ;
FAST very good and clear a great unexpensive job!!! very recomended for all people who are preofessional or hobbists as me!!!!!!
 ;
Thank you very much for this Service Manual, it helped us a lot to repair the M-4318!
...BUT: The parts list is missing and the free parts katalog on web isn't complete, so now we don't know the part numbers of the defect parts :(
We had to build them out of a working machine, and need the numbers to reorder the missing parts now.
 ;
Very good manual with clear electrical diagrams. Thanks owner-manuals.
5. Check the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 2.4 ± 0.7 Vp-p.
S-curve waveform symmetry
Traverse waveform
A B
A within 2.4 ± 0.7 Vp-p B
level: 300 ± 100 mVp-p
specified level : � ������ � 100 = less than ± 7% A�B 2 (A+B) � A+B= 300 ± 100 mVp-p 6. Remove the lead wire connected in step 1. Focus/Tracking Gain Adjustment (RV102, RV103) This gain has a margin, so even if it is slightly off. There is no problem. Therefore, do not perform, this adjustment. Please note that it should be fixed to mechanical center position when you moved and do not know original position. Adjustment Location :
6. After check, remove the lead wire connected in step 2. Note : � Try to measure several times to make sure that the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform. RF Level Check
oscilloscope BD (CD) board TP (RF) TP (VC)
+ �
[BD (CD) BOARD] � Side B �
Procedure : 1. Connect oscilloscope to test point TP (VC) and TP (RF) on BD (CD) board. 2. Turned Power switch on. 3. Put disc (YEDS-18) in and press the · (CD) key. 4. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not. Note : Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.
FOK
IC102 TEI FEI RV102
RF
IC101 FEO
RF signal waveform
VOLT/DIV: 200 mV TIME/DIV: 500 ns
RV101
TEO RV103
VC
IC104
level: 1.3 ± 0.3Vp-p
E-F Balance (Traverse) Check
oscilloscope (DC range) BD (CD) board TP (TEO) TP (VC)
+ �
Procedure : 1. Connect the TP (TEI) and TP (VC) with lead wire. 2. Connect oscilloscope to test point TP (VC) and TP (TEO) on BD (CD) board. 3. Turned Power switch on. 4. Put disc (YEDS-18) in and press the · (CD) key. 5. Confirm that the oscilloscope waveform is symmetrical on the top and bottom in relation to 0 Vdc, and check this level.
� 27 �
|
|
 |
> |
|