Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I am very pleased with the service manual for my RT-909. This was an easy purchase and great procuct, and much cheaper than other venues i had looked at. This web site is now listed in my favorites list. KEEP UP THE GOOD WORK. THANKS. J. BROWN
 ;
A very well written and easy to understand manual.
 ;
There was no problem at all.After paying i had to wait only a few hours,than i could
download the manual in best pdf-quality.
Thank You !
 ;
I found this service manual to be complete in every detail except for troubleshooting charts. It would be helpful if it had a set of troubleshooting charts; however it is a very good manual otherwise and for the price it is very well worth it.
 ;
Complete manual included schematics layouts and alignment procedure, clear to read and magnify, extremely pleased with manual and owner manual . com's service
SECTION 4 ELECTRICAL ADJUSTMENTS
CD SECTION
Note : 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. S-Curve Check
E-F Balance (1 Track jump) Check
Oscilloscope BD board TP(FEO) TP(VC)
Note : Clear RF signal waveform means that the shape � � � can be clearly distinguished at the center of the waveform.
RF signal waveform VOLT/DIV : 200mV TIME/DIV : 500ns
Level : 1.45 ± 0.3Vp-p
Oscilloscope BD board TP(TEO) TP(VC)
Procedure : 1. Connect oscilloscope to TP (FEO). 2. Connect between TP (FEI) and TP (VC) by lead wire. 3. Connect between TP (AGCCON) and TP (GND) by lead wire. 4. Turn ?/1 button on. 5. Load a disc (YEDS-18) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 6. Confirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 4 ±1 Vp-p.
S-curve waveform Symmetry
Procedure : 1. Connect oscilloscope to TP (TEO) and TP (VC). 2. Turned ?/1 button on. 3. Load a disc (YEDS-18) and playback the number five track. 4. Press the 7 button. (Becomes the 1 track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
1 track jump waveform Center of waveform B A (DC voltage) 0V
A B Wthin 4 ±1Vp-p
Level=1.3 ±0.6 Vp-p Symmetry
Specified level: A � 100 = less than ± 22 % B
6. After check, remove the lead wire connected in step 1.
7. After check, remove the lead wire connected in step 2 and 3. Note : � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform. RF Level Check
Oscilloscope BD board TP(RF) TP(VC)
Adjustment Location: [BD BOARD] (Conductor Side)
TP (RF) TP (VC)
Procedure : 1. Connect oscilloscope to TP (RF). 2. Connect between TP (AGCCON) and TP (GND) by lead wire. 3. Turned ?/1 button on. 4. Load a disc (YEDS-18) and playback. 5. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not. 6. After check, remove the lead wire connected in step 2.
TP (GND)
TP (AGCCON) TP (FE0) IC103 IC101 TP (TEO)