Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great manual very clear copied. You are making an incredible job. I appreciate a lot the rapidity and your efficiency. Thanks a lot
 ;
Good pdf of the service manual for this unit. Includes disassembly instructions, full schematics, board layouts, parts lists and diagnostic information. Some information is in the pdf twice (single pages, and split pages), but that could be how it was originally generated by panasonic, or perhaps the idea is to make it eaiser to put onto 8.5 x 11" pages.
Information was exactly what I needed. Delivery was overnight (less than 12 hours) and I was happy with the process.
 ;
5 STARS for FAST DELIVERY, BEST PRICES and QUALITY PRODUCT. Item was exactly as described with superb resolution. Will definitely source all my future requirements from this website. Thanks a lot owner-manual.com!
 ;
OEM manual provided all schematics, board layouts and component specs necessary to facilitate unit maintenance. All pages were clear and readable.
 ;
Good condition and quality. Hard to find anywhere in Internet, only on this site.
HCD-X1
MIRR time Adjust Menu 1. 2. 3. 4. 5. CD MIRR time Check: DVD MIRR time Check: Threshold:75 Save to EEPROM Default set MIRR time
17. Take out the CD test disc (YEDS-18). 18. Release the MIRR time Adjust Menu mode.
5. EXECUTING IOP MEASUREMENT
In order to execute IOP measurement, the following standard procedures must be followed. 1. Set to the Drive Manual Operation mode. 2. Press the [3] button on the romote commander, and the following Manual Adjust menu will be displayed. Manual Adjust 1. Track Balance Adjust: 2. Track Gain Adjust: 3. Focus Balance Adjust: 4. Focus Gain Adjust: 5. Eq Boost Adjust: 6. Iop: 7. TRV. Level: 8. S curve(FE) Level: 9. RFL(PI) Level: 0. MIRR Time: � � Change Value [RETURN]Return to previous menu 3. Press the [6] button on the romote commander to select the �6. Iop�. 4. Wait for hexadecimal Value to display on the screen. Manual Adjust 1. Track Balance Adjust: 2. Track Gain Adjust: 3. Focus Balance Adjust: 4. Focus Gain Adjust: 5. Eq Boost Adjust: 6. Iop: YY ZZ 7. TRV. Level: 8. S curve(FE) Level: 9. RFL(PI) Level: 0. MIRR Time: � � Change Value [RETURN]Return to previous menu 5. Convert each value (YY and ZZ) from hexadecimal to decimal using conversion table. 6. Substract between these two values (YY and ZZ). 7. If the remainder is smaller than 93 (decimal), then it is OK. However if the value is higher than 93, then the BU (base unit) is defective and need to be change. 8. Release the Manual Adjust menu mode.
[Open]Tray open [Close]Tray close [0]Return to previous menu 5. Insert the DVD test disc (HLX-504) (Part No. J-6090-088-A). 6. Press the [2] button on the romote commander to select the �2. DVD MIRR time Check�. 7. Wait for hexadecimal value to display on the screen. 8. Check the value (##) of DVD MIRR time on the screen. If ## is 28 to 70, go to next step. If it is not so, return to step 5. MIRR time Adjust Menu 1. 2. 3. 4. 5. CD MIRR time Check: DVD MIRR time Check: $$ ## Threshold: Save to EEPROM Default set MIRR time
[Open]Tray open [Close]Tray close [0]Return to previous menu 9. Press the [4] button on the romote commander to select the �4. Save to EEPROM�. 10. Check that $$ is the same as the value of ## on the screen. If it is not so, return to step 5. 11. Take out the DVD test disc (HLX-504) and insert the CD test disc (YEDS-18) (Part No. 3-703-998-01). 12. Press the [1] button on the romote commander to select the �1. CD MIRR time Check�. 13. Wait for hexadecimal value to display on the screen. 14. Check the value (@@) of DVD MIRR time on the screen. If @@ is 5A to E8, go to next step. If it is not so, return to step 11. MIRR time Adjust Menu 1. 2. 3. 4. 5. CD MIRR time Check: && @@ DVD MIRR time Check: $$ ## Threshold: Save to EEPROM Default set MIRR time
[Open]Tray open [Close]Tray close [0]Return to previous menu 15. Press the [4] button on the romote commander to select the �4. Save to EEPROM�. 16. Check that && is the same as the value of @@ on the screen. If it is not so, return to step 11.