Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Owner-manuals.com is the best Possibility to give vantage HIGH CLASS Elektronic COMPONENTS
a new Life.Thanks alot for your perfekt Service.
 ;
I am proud of you. In the future, I benefited from your services.
 ;
I found this manual to be complete in every detail. Besides the schematic it has a complete set of alignment instructions which are easy to understand. It also includes a complete parts list as well as an explanation of how the power supply and safety shutdown circuits operate. Even a schematic of the tuner is included.
 ;
The product was good and just what I needed, however I had moderate difficulty with the down load because the sight would not recognize my pass word. I was finally given a direct link to the manual and that worked.
 ;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
HCD-XGV50
CD SECTION
Note : 1. CD Block is basically designed to operate without adjustment. Therefore, check each item in order given. 2. Use LUV-P01 (4-999-032-01) unless otherwise indicated. 3. Use an oscilloscope with more than 10M� impedance. 4. Clean the object lens by an applicator with neutral detergent when the signal level is low than specified value with the following checks. S-Curve Check
Oscilloscope BD board
Note: Clear RF signal waveform means that the shape ��� can be clearly distinguished at the center of the waveform.
VOLT/DIV : 200mV TIME/DIV : 500ns
level : 1.45 ± 0.3Vp-p
E-F Balance (1 Track jump) Check
oscilloscope BD board
TP(FE) TP(DVC)
TP(TE) TP(DVC)
Procedure : 1. Connect oscilloscope to TP (FE). 2. Connect between TP (FE) and TP (DVC ( 1.65 V)) by lead wire. 3. Press the \/1 button to turn the power ON. 4. Load a disc (LUV-P01) and actuate the focus search. (In consequence of open and close the disc tray, actuate the focus search) 5. Confirm that the oscilloscope waveform (S-curve) is symmetrical between A and B. And confirm peak to peak level within 2 ±0.5 Vp-p.
S-curve waveform symmetry
Procedure: 1. Connect oscilloscope to TP (TE) and TP (DVC) board. 2. Press the \/1 button to turn the power ON. 3. Load a disc (LUV-P01) and playback the number nine track. 4. Press the bB button. (Becomes the 1track jump mode.) 5. Confirm that the level B and A (DC voltage) on the oscilloscope waveform.
center of waveform B 0V A (DC voltage)
A within 4 ±1Vp-p B
B=1.3 ± 0.6Vp-p
Specified level: A � 100=less than � 22% B
symmetry
6. After check, remove the lead wire connected in step 2. Note : � Try to measure several times to make sure than the ratio of A : B or B : A is more than 10 : 7. � Take sweep time as long as possible and light up the brightness to obtain best waveform. RF Level Check
oscilloscope BD board TP(RFDC) TP(RFAC)
Checking Location: [BD BOARD] (SIDE B)
DVC
SE
FE
Procedure : 1. Connect oscilloscope to TP (RFDC) and TP (RFAC). 2. Press the \/1 button to turn the power ON. 3. Load a disc (LUV-P01) and playback. 4. Confirm that oscilloscope waveform is clear and check RF signal level is correct or not.
TE RFDC RFAC DVC
20
|
|
 |
> |
|