|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was searching a way to modify the original phono-in entry (for connection of vynil disc player, with RIAA equalization) to a line-in entry (for connection of modern analog entries, eg. ipod, mp3player).
This service manual gave me the correct hints.
It contains very useful infos for repairing and modifing the hi-fi, such as disassembling instructions, block diagrams, schematic diagrams, PCB prints, replacement parts list.
Very good!
 ;
Great Job!!! clear and efficient as always!!
it is really nice to have peple that are doing such a good work!!!!!
 ;
I must admit, I was very skeptical... $4.99 for a 74 page service manual. I've seen some very poorly scanned manuals on the Internet, but this one is VERY good quality! Even when zooming into 500%. Great Deal!
 ;
Very good detail, Quick service response. A useful service manual with all details. I recomend this service.
 ;
As Always you can find here manuals even of difficult TV scheme which are scan in almost perfect way.clear and fast!!!!!
Great work thanks!
6-3. Self Diagnostics of BKDS-2010 Not Using Terminal
6-3. Self Diagnostics of BKDS-2010 Not Using Terminal
BKDS-2010 is able to check the following functions without using the terminal. Checks 1. SW SCAN TEST 2. 7SEG TEST 3. VOLUME TEST 4. LCD TEST 5. MEMORY TEST 1. SW SCAN TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [NORM] button on the control panel, connect the AC inlet to the rear panel to enter the SW SCAN TEST mode. For the details of this test, refer to the step (3) and later of �1. SW SCAN TEST� in �6-2-3. Self Diagnosis�. 2. 7SEG TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the NORM button on the control panel, connect the AC inlet to the rear panel to enter REV the 7SEG TEST mode. For the details of this test, refer to the step (3) and later of �4. 7SEG TEST� in �6-2-3. Self Diagnosis�. 3. VOLUME TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [REV] button on the control panel, connect the AC inlet to the rear panel to enter the VOLUME TEST mode. For the details of this test, refer to the step (3) and later of �5. VOLUME TEST� in �6-2-3. Self Diagnosis�. 4. LCD TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [MULTI] button on the control panel, connect the AC inlet to the rear panel to enter the LCD TEST mode. For the details of this test, refer to the step (3) and later of �6. LCD TEST� in �6-2-3. Self Diagnosis�.
6-48
HDS-7150/7100
 $4.99 HDS-7100 SONY User Guide It's a complete guide ( also known as operating manual or owner's manual), and it's in PDF format. A…
|
|
 |
> |
|