I bought the service-manual of the sony ICB-1020(an old transmitter-receiver) at "www.Owners-Manual.com", I found the service-manual for a fairly cheap price(in comparison with other sellers). I filled in some questions, payed the order with Ideal, and within 24 hours I had my service manual. I was very happy:In no time I had my service-manual and everything, but literally everything was noted down in the manual; the electronic scheme, the parts list, etcetera.
A very practical, reference-document.
 ;
This comprehesive service maual was greatly appreciated, as was the digital download.
 ;
Good en helpfull black and white scanned Srfvice manual of the Philps D8444. Quick service and delivery
 ;
Scan was really good quality, easy to read, download easy
 ;
very good manual as always. easy to read, detailed and includes schematic
6-3. Self Diagnostics of BKDS-2010 Not Using Terminal
6-3. Self Diagnostics of BKDS-2010 Not Using Terminal
BKDS-2010 is able to check the following functions without using the terminal. Checks 1. SW SCAN TEST 2. 7SEG TEST 3. VOLUME TEST 4. LCD TEST 5. MEMORY TEST 1. SW SCAN TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [NORM] button on the control panel, connect the AC inlet to the rear panel to enter the SW SCAN TEST mode. For the details of this test, refer to the step (3) and later of �1. SW SCAN TEST� in �6-2-3. Self Diagnosis�. 2. 7SEG TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the NORM button on the control panel, connect the AC inlet to the rear panel to enter REV the 7SEG TEST mode. For the details of this test, refer to the step (3) and later of �4. 7SEG TEST� in �6-2-3. Self Diagnosis�. 3. VOLUME TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [REV] button on the control panel, connect the AC inlet to the rear panel to enter the VOLUME TEST mode. For the details of this test, refer to the step (3) and later of �5. VOLUME TEST� in �6-2-3. Self Diagnosis�. 4. LCD TEST Procedure (1) Check that the AC inlet is disconnected from the rear panel of the BKDS-2010. (2) While pressing the [MULTI] button on the control panel, connect the AC inlet to the rear panel to enter the LCD TEST mode. For the details of this test, refer to the step (3) and later of �6. LCD TEST� in �6-2-3. Self Diagnosis�.
6-48
HDS-7150/7100
|
|
 |
> |
|