This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
6-1. Tape Path Adjustment 6-1-2. Tape Running Check and Adjustment
6 TG-3 (Exit guide) 5 Lead of drum exit side 7 TG-4
8 TG-5 (Threading roller)
9 TG-10 !/ Tape guide
Capstan AT erase head AT head Pinch roller
Cassette
Spec. 2 : 5 Lead of drum exit side The tape runs without any curl at the lead nor rising from the lead. 6 TG-3 (Exit guide) The tape runs in contact with the upper flange. The tape curl is less than 1/10 of the tape width. 7 TG-4 The tape runs in contact with the lower flange. The tape curl is less than 1/10 of the tape width. 8 TG-5 (Threading roller) The tape runs without any curl at the upper and lower flanges.
Spec. 3 : PLAY mode 9 TG-10 The tape runs without contacting the upper and lower flanges. !/ Tape guide at T side The tape runs without any curl at the upper and lower portions of the tape guide.
Tape Running Check at Drum Exit Side
6-12
HDW-500E MMP2V1
|