Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
 ;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
CHAPTER 7 TROUBLESHOOTING
I-6
Black and blurred vertical streaks
User Check (1) Clean the corona wire in the drum unit. (2) Check that the corona wire cleaner is at the home position. (3) Check that the toner cartridge is not empty. (4) The drum unit may be damaged. Install a new drum unit. (5) The toner cartridge may be damaged. Install a new toner cartridge.
<Scanning> Possible cause Dirt on the CIS window Dirt on the document pressure bar Scratch on the document pressure bar <Printing> Possible cause Corona failure Step 1 Check Is the vertical block streak about 10mm wide? (Check if the wire cleaner is at its home position.) Is the paper cassette or feed system on the drum unit dirty with toner? Is the drum surface scratched? Is the drum surface dirty with toner in streaks? Is the surface of the heat roller scratched? Result Yes Remedy Return the wire cleaner to its home position. Step 1 2 Check Is there any dirt on the CIS window? Is the document pressure bar dirty? Are there any scratches on the document pressure bar? Result Yes Yes Remedy Clean the CIS window. Clean the document pressure bar. Replace the document pressure bar.
3
Yes
Dirt in the paper feed system Scratch on the drum Cleaning failure Scratch on the heat roller
2
Yes
Clean the toner off.
3 4 5
Yes Yes Yes
Replace the drum unit. Replace the drum unit. Replace the fixing unit.
NOTE: � If you print the same pattern continuously, the drum will be worn and black vertical streaks will appear on the paper. � This problem may occur with noise due to the corona wire dirty. In that case, clean the corona wire with the wire cleaner.
7-32
|
|
 |
> |
|