This manual covers the main equipment features only. While it also includes the procedure for saving and loading from the now long obsolete memory cards it does not mention the how to operate with the optional floppy drive interface so I am still at a loss about how to use this! Note that there is a separate manual covering the MIDI interface and programming via the keyboard, not included in this download. You will also need to get hold of this if you want to use the MIDI interface properly. Basically there is little difference between this manual and the free to download manual for the similar PR60 model.
 ;
Good list of manuals. I found a very rare one and easily get. Should be promptly to download, as we must to wait hours even after confirmed payment.
INSTALLATION
How to Install the Unit
1. To prevent vibration and noise, make sure the unit is installed securely and firmly 2. Install the unit where the sunlight does not shine directly on the unit. 3. The outside of the cabinet must extend outward for at least 28cm (11") and there should be no obstacles, such as a fence or wall, within 50.8cm (20") from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
Cooled air Fence Awning Heat radiation
76.2cm (30")~ 152.4cm (60")
About 12.7mm (1/2") Over 50.8cm (20")
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure. 4. Install the unit a little slanted so the back is slightly lower than the front (about 12.7cm (1/2")). This will force condensed water to flow to the outside. 5. Install the unit with the bottom about 76.2cm (30")~152.4cm (60") above the floor level.
Window Requirements
NOTE: All supporting parts should be secured to firm wood, masonry, or metal. This unit is designed for installation in standard double hung windows with actual opening widths from 55.88cm (22") to 91.44cm (36"). The top and bottom window sash must open sufficiently to allow a clear vertical opening of 38cm (15") from the bottom of the upper sash to the window stool.
Interior wall 47cm (181/2") min. (Without frame curtain)
55.8cm (22") to 91.44cm (36")
Features and Installation
38cm (15") min Stool (With frame curtain)
Offset 12.7mm (1/2") to 31.8mm (11/4") Sill Exterior