let's say first that i do not need to have a credit for my opinion, i am a retired sparkie and i voluteerd to fix an electronic device for a local "Youthgroup",as no diagram was present i checked the "net" and gambled on this site and paying some fee via PayPall, i was gladly surprised that the manual arrived as was stated, GOOD SHOW, and best wishes, John
 ;
I had been looking for a Manual for my CS2150 for quite a while -- in fact I had just about given up. I saw this site and decided to download the Manual. When I Received it by Email I was really pleased with what I got, with the result that My Kenwood 'Scope is now 100% repaired and working well. As an AV Serviceman, you need a good 'scope, and thanks to this site, and the Service Manual, I have been able to repair it. The Manual was a copy of the Factory Original and the copy was very clear, especially in the area of the Circuit Schematics, where You really need to be sure of what You are looking at.
 ;
I recently purchased a manual for a Samsung DLP tv to help with a trouble shooting problem I was having. Every tv repair shop wanted close to $400.00 for the fix, but after I found Owner-Manuals.com I hit pay dirt. The manual they had for me to purchase and download was a complete service manual for the exact tv I needed. It was complete with wiring diagrams, schematics, and even part numbers. If your the fix it yourself type I highly recommend trying to find any manual here before paying someone else to fix whatever problem your having.
 ;
Once again, excellent price and manual delivered in a timely manner and as advertised!
 ;
Outstanding quality manual. This is the exact documentation I needed to service my AKAI GX-210D. This is a PERFECT COPY of the service manual for my machine. Outstanding service. Thank-you!
3.5.8 Sub DET [HR-S6700KR]
Signal Mode Equipment Adjustment part Specified value Adjustment tool (A) (B) (C) (F) (G) (H) � RF signal (sound carrier: S2) � Tuner � EE � Audio level meter � IC1501 pin 26 � T1501 (SUB DET) � Minimum distortion � LPF (30 kHz), HPF (400 Hz)
3.6 SYSCON CIRCUIT Note: � When perform this adjustment, remove the Mechanism assembly. 3.6.1 Timer clock
Signal Mode Equipment (A) (B) (C) � No signal � EE � Frequency counter � IC3001 pin61 � IC3001 pin24 � C3026 + and � � C3025 (TIMER CLOCK) � 1024.008 ± 0.001 Hz (976.5549 ± 0.0010 µsec)
Measuring point (D)
(1) Set the sound carrier of the RF signal generator to S2. (2) Connect the adjustment tool (H) to the measuring point (D). Then connect the equipment (C) to the adjustment tool (H). (3) Adjust the Adjustment part (F) so that the distortion level of the measuring point (D) becomes the specified value (G). 3.5.9 Pilot VCO [HR-S6700KR]
Signal Mode Equipment (A) (B) (C) � No signal � Tuner � EE � Frequency counter � IC1501 pin 11 � C1510 (+) terminal � C1510 (�) terminal � VR1502 (PILOT VCO) � 210 ± 5 Hz
Measuring point (D1) Short point (D2) (D3) Adjustment part (F) Specified value (G)
Measuring point (D1) Short point (D2) (D3) Adjustment part Specified value (F) (G)
(1) Connect the frequency counter to the measuring point (D1). (2) Connect the short wire between the short point (D2) and Vcc (5V). (3) Short the leads of capacitor (D3) once in order to reset the microprocessor of the SYSCON. (4) Disconnect the short wire between the short point (D2) and Vcc then connect it again. (5) Adjust the Adjustment part (F) so that the output frequency becomes the specified value (G).
(1) Connect the short wire between the short points (D2) and (D3). (2) Connect the equipment (C) to the measuring point (D1). (3) Adjust the Adjustment part (F) so that the frequency of the measuring point (D1) becomes the specified value (G). (4) Disconnect the short wire between the short points (D2) and (D3). 3.5.10 Separation [HR-S6700KR]
Signal Mode Equipment Adjustment part Specified value Adjustment tool (A) (B) (C) (F) (G) (H) � Sweep generator output (90 dB, 1 kHz) � EE � Oscilloscope � IC1501 pin 19 � VR1501 (SEPARATION) � Minimum level � Sweeper probe (See Fig. 3-5-10a.)
Measuring point (D)
Shorter than 8 cm
Shield
C : 1000 P R : 75� Earth
Out
Shorter than 5 cm
Fig. 3-5-10a
Sweeper probe
(1) Use the adjustment tool (H), supply 1 kHz R-only modulated IF signal to IF terminal of U/V tuner (front end). (2) Connect the equipment (C) to the measuring point (D). (3) Adjust the Adjustment part (F) so that the output level of the measuring point (D) becomes the specified value (G). 3-7
|
|
 |
> |
|