This manual is accurate and of high quality. It is only volume 2 of the service manual. This is schematic, parts lists, and exploded mechanical drawings. The theory of operation and the diss-assembly instructions are in volume 1. The unit can be tricky to dis-assemble portions of so the volume 1 manual can be important. The product description of the manual is accurate but it does not say anything about volume 1 and the image of the front page does clearly say Volume 2.
 ;
Wellll again thank you very much fast and effective. Clear and well done for such an old TV!!!!
 ;
It has all the information you will need to fix it. The main circuit diagram is only A4 but being a PDF, you can print it to any size - I did it on two sheets of A3 and it didnt lose any detail - just made it readable when pinned up above the bench. I've found the fault, just need to buy some obscure bits to get it going again!
I cant fault the process, I paid for the manual in the morning and it was ready to download by lunch time.
 ;
Very good copy in a 54 pages PDF archive. This is my sixth purchase here. :)
4.4.5 Optimization adjustment of Front End parameter Adjustment to optimize Front End parameter must be performed in each mechanism assembly of this model for high-speed starting.Please perform optimization according to the following procedures just after all-initialization is completed and when FL display shows anything except "�0" (For example when FDP shows "�1", "�2", and "�3") at test mode. (1) Press "POWER" button of the front panel to turn the main body on (not to set the main body at test mode). (2) Insert the test disc VT-501 or commercial dual-layer DVD software. (3) Remove the disc when the FL display changes from "READ" to disc information. (4) Perform the same procedures as in (2) and (3) above by using the test disc CTS-1000 or commercial CD-DA software. (5) Set the main body at test mode, and check that the FDP shows "�0". NOTE: Status of this adjustment can be judged by the number displayed at test mode as follows: DVD adjustment Adjusted Not adjusted Adjusted Not adjusted CD adjustment Adjusted Adjusted Not adjusted Not adjusted FDP at test mode �0 �1 �2 �3
NOTE: As for a disc used for adjustment, � Disc should be mounted. ("Mounting" means to display "READ" after the disc is inserted and then display the disc information.) Disc need not be played. � If you do not have test disc either VT-501 (DVD) or CTS-1000 (CD-DA), use a commercial disc (for DVD, dual-layer software) after seeing and checking that the disc is neither curved nor foreseen that it may shake at the time of playback.If you use a disc with bad features, starting time may be slow or disc may not be read. 4.4.6 (1) (2) (3) Display of current value of laser Set the main body at test mode. Press "SET UP MENU" key of the remote controller three times. Then, FDP is displayed "CHECK". The laser current value can be switched between the value of CD and that of DVD by pressing the following key of the remote controller.
FDP (Example)
2530
****
Remote controller "4" key --- Laser of CD Remote controller "5" key --- Laser of DVD
The number shown in the FDP shows mA of current value of laser.The first two numbers ("25" in "2530") shows current value of laser at the time of adjustment after the latest all-initialization, 25mA in this example.The last two numbers ("30" in "2530") shows the present current value of laser, 30mA in this example.The first two numbers ("25" in "2530") usually shows current value of laser at the time of shipment, so you can see how the product has been deteriorated by comparing the first two numbers ("25" in "2530") and the last two numbers ("30" in "2530"). CD: The laser current value of 65 mA or less is normal.The laser current value of over 66 mA is not normal. Laser diode of the pickup has been deteriorated. DVD: The laser current value of 80 mA or less is normal.The laser current value of over 81 mA is not normal. Laser diode of the pickup has been deteriorated. To return to test mode, press "STOP" button of the front panel.
1-22 (No.YD001)
|
|
 |
> |
|