Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This Service manual is very well scanned and its clean to read, no any anti-theft words that un-english could understand. I got my CCD600 working with this manual and it´s clear shematics :)
 ;
I was very pleased with the service provided and was surprised at how good the quality was of the manual. I thought it may be a third generation copy or so, but it is as good as the websites that charge 3 times this much. I repair some electronics for family and friends without charge, so this is perfect for me. Thank you very much.
 ;
The service was great and the document was also great. Highly recommend!!!!
If anyone has a users manual... Please email me. need one. $ [email protected]
 ;
I needed a service manual as the display on my oscilloscope was very dim. I thought I'd give owner-manuals.com a try, as they advertised a huge number of manuals. Sure enough they had one listed. I bought it hoping it would be useful... actually, I bought it hoping it would be readable! I've had manuals from online sources in the past, and been very disappointed. Not this time! An excellent manual, complete, and very readable. Using it I fixed my 'scope, and as such the manual was an investment that paid off manyfold. Do I have any complaints? One very minor one - The circuit diagrams could have been scanned at a higher resolution, as some of the details were a little difficult to make out - not impossible, just not as easy as my old eyes would like! Overall, I'm very satisfied with my manual, and I will certainly be using this company again. Well done.
 ;
I Have looked for this manual for quiet a while now, I have finally found it here. I believe this is the only place they have them in a very nice scan, pages are very clear to read, some of the pages are a bit tilted but overall it is great to have this manual available for purchase. Thanks
4.4.5 Optimization adjustment of Front End parameter Adjustment to optimize Front End parameter must be performed in each mechanism assembly of this model for high-speed starting.Please perform optimization according to the following procedures just after all-initialization is completed and when FL display shows anything except "�0" (For example when FDP shows "�1", "�2", and "�3") at test mode. (1) Press "POWER" button of the front panel to turn the main body on (not to set the main body at test mode). (2) Insert the test disc VT-501 or commercial dual-layer DVD software. (3) Remove the disc when the FL display changes from "READ" to disc information. (4) Perform the same procedures as in (2) and (3) above by using the test disc CTS-1000 or commercial CD-DA software. (5) Set the main body at test mode, and check that the FDP shows "�0". NOTE: Status of this adjustment can be judged by the number displayed at test mode as follows: DVD adjustment Adjusted Not adjusted Adjusted Not adjusted CD adjustment Adjusted Adjusted Not adjusted Not adjusted FDP at test mode �0 �1 �2 �3
NOTE: As for a disc used for adjustment, � Disc should be mounted. ("Mounting" means to display "READ" after the disc is inserted and then display the disc information.) Disc need not be played. � If you do not have test disc either VT-501 (DVD) or CTS-1000 (CD-DA), use a commercial disc (for DVD, dual-layer software) after seeing and checking that the disc is neither curved nor foreseen that it may shake at the time of playback.If you use a disc with bad features, starting time may be slow or disc may not be read. 4.4.6 (1) (2) (3) Display of current value of laser Set the main body at test mode. Press "SET UP MENU" key of the remote controller three times. Then, FDP is displayed "CHECK". The laser current value can be switched between the value of CD and that of DVD by pressing the following key of the remote controller.
FDP (Example)
2530
****
Remote controller "4" key --- Laser of CD Remote controller "5" key --- Laser of DVD
The number shown in the FDP shows mA of current value of laser.The first two numbers ("25" in "2530") shows current value of laser at the time of adjustment after the latest all-initialization, 25mA in this example.The last two numbers ("30" in "2530") shows the present current value of laser, 30mA in this example.The first two numbers ("25" in "2530") usually shows current value of laser at the time of shipment, so you can see how the product has been deteriorated by comparing the first two numbers ("25" in "2530") and the last two numbers ("30" in "2530"). CD: The laser current value of 65 mA or less is normal.The laser current value of over 66 mA is not normal. Laser diode of the pickup has been deteriorated. DVD: The laser current value of 80 mA or less is normal.The laser current value of over 81 mA is not normal. Laser diode of the pickup has been deteriorated. To return to test mode, press "STOP" button of the front panel.
1-22 (No.YD001)
|
|
 |
> |
|