Text excerpt from page 6 (click to view)
ADJUSTMENT
MECHANICAL EXPLODED VIEW 1 / 1
A MAIN C.B
P HEAD
VOLUME
IC 1
VR1
2 FWD
PHONES
SFR 51
J1
1 2
1
1. Tape Speed Adjustment Settings : � Test tape :
Method :
TTA � 100 (Tape center) � Test point : Phones Jack (J1) � Adjustment location : SFR51 � MSP : CLASSIC � Tape selector : NORM � Volume : Non � clip (MAX � 10dB) Play back the test tape and adjust SFR51 so that the frequency becomes 3000Hz ± 10Hz. Then confirm WOW is less than 0.50%.
TTA � 330 / TTA � 420 CLASSIC MAX NORM Head azimuth adjustment screw Play back (FWD) the test tape and adjust screw so that the 8kHz signal output is maximum.