The service manual is a good quality scan of the Blaupunkt RTV-404, which is electrically and mecanically identical to the Panasonic NV-830.
 ;
completo manual bien detallado y de buena calidad de impresion , se echa en falta los esquemas de placa y parte de algun diagrama.
 ;
perfecto manual ,completo y detallado de muy buena calidad de impresion, ideal en una palabra.
 ;
un manual completo con una calidad de imagen buena con explicaciones en varios idiomas de los ajustes y detalles en conjunto un OK.
 ;
Good copy, clear and has all necessary information. Very happy with the purchase
TEST MODE
This model has a test mode function in the disassembled condition.
Screw
TP701 Screw
TEST
1. How to use the test mode: � Short the test land in the MAIN C.B. � Auto-stop function is not detected by micro-computer while test mode is active. Note: Make sure that the test land is opened after the test mode is de-activated. (Auto-stop function is not available with shorted land condition.) 2. How to disassemble the circuit board. � Removes the soldering part in the MAIN C.B . � Removes two screws.