Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
 ;
We received the manual in a timely manner and it was exactly what we were expecting.
 ;
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
 ;
Very good scanning quality. All schematics are very legible. Worth every cent !
 ;
Excellent quality, very quick download turnaround, will definately use again.
ADJUSTMENT
A MAIN C.B
11
VOLUME
4 3 1
2
J101 PHONES
VR101
1 1
2
TP2 (RCH) TP1(LCH) TP3 (GND)
2 2
SFR301
2
1. Dolby Level Adjustment <AE> Setting : � Test tape : TTA � 200 � Test point : TP1 (RCH), TP2 (LCH) � DSL : OFF � Tape selector : NORMAL (AUTO) � Dolby SW : OFF � Volume : MIN � Adjustment points : Soldered patterns 1 � 4 Procedure : Short the patterns via solder as shown in the table so the Dolby NR level is 32 mV ± 1.0 dB. Adjust so the specifications are satisfied in both the forward and reverse directions. Connect 10µF /16V coupling capacitors between test points and test equipment (connect the positive terminals to the test points). SOLDER PATTERN 1 � 4 STANDARD : 24.5 ± 1.0dB SOLDER POINT INCRESE LEVEL 1 only + 0.8 dB Lch
2 1 3
2. Tape Speed Adjustment Settings : � Test tape : TTA � 100 (Tape center) � Test point : Phones Jack (J101) � Adjustment location : SFR301 � Dolby : OFF � DSL : OFF � Tape selector : NORMAL (AUTO) � Volume : MAX Method : Play back (FWD) the test tape and adjust SFR301 so that the frequency becomes 3015 Hz ± 10 Hz. Then confirm WOW is less than 0.50%.
only and 2 only only and 4
+ 1.5 dB + 2.5 dB + 0.8 dB + 1.5 dB + 2.5 dB
Rch
4 3