There are currently no product reviews.
 ;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
 ;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
 ;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
 ;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
 ;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
HTP-120 IDLING ADJUSTMENT
Adjustment of Idling current
1). Cancel the Auto standby ON mode. P604 is short. 2). Connect the DC volt meter to P531. 3). At the no load and no input signal condition. 4). Turn on the power switch. And adjust 0.25mV by trimmer (R544) on Main PC board. 5). After heat run for about 5 minutes, and set 4mV by R544 again.
D911 C912
Printed circuit board view from component side
C911
NCAF-7455
Trimmer
P604
Q623
R544
Q514
Q513
P623
P531
Q516 Q952 Q515
Q951
Q541
DC Volt meter
Setting position of shipping
Output level ---------------------- MIN