Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
 ;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
 ;
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
 ;
Very good manual, at a very good price. Received in a timely manner
 ;
Only thу cover has poor quality, internal material has excellent quality - exactly what I needed
Thanks!
HT-R430 OPERATION CHECK-3
CONTROL OF POWER SUPPLY (OUTPUT SENSOR AND THERMAL SENSOR)
[When] 1. Exchange power transistors (Q6050 - Q6065). 2. Exchange power amplifier PC board ass'y (NAAF-8523). 3. Exchange thermal sensor PC board ass'y (NAETC-8526). [Procedure] <Note> No output. No input. Output sensor 1. Press and the hold down the CD button, then press the STANDBY/ON button when the unit is Power ON. " Test - _ " is displays it only for 5 seconds.
Te st - _
Blinks
2. Press the VIDEO 3 button, while the character of " Test - _ " is displayed. Unit will be in the state of " Test-4-00 ".
Te st - 4- 00
3. Repeatedly press TONE+ button until the character of " Test-4-37 " is displayed.
Te st - 4- 37
4. Adjusts MASTER VOLUME to Max. position. At this time, check the character of " FM STEREO " displayed. And, check relay RL6901 and RL6902 are turned off in 2 - 3 seconds. FM STEREO
Te st - 4- 37
5. Press the STANDBY/ON button.
Turn off
Clear
Thermal sensor
1. Press and hold down the DISPLAY button, then press the STANDBY/ON button when the unit is power ON. " V er. 0.5 0/0 5131a " is displays it only for 2 seconds. <Ex.>
V er. 0.50/05131a
2. Press the TONE button, while the character of " Ver.0.50/05131a " is displayed. <Ex.>
T: 25 C/ 77 F
3. Check the displayed temperature is +/-20 C of the ambient temperatures. 4. Press STANDBY/ON button.
Turn off
Clear
|
|
 |
> |
|