Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
We received the manual in a timely manner and it was exactly what we were expecting.
 ;
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
 ;
Very good scanning quality. All schematics are very legible. Worth every cent !
 ;
Excellent quality, very quick download turnaround, will definately use again.
 ;
This is a awesome quality scan of the original Service Manual for Technics 8099.
Contains the circuit diagram, PCB layout, adjust/tune instructions as well.
Since this is my first buy here, i'm really glad! This site do works as intended/described, it's definitely not scam!
Мои рекомендации! Все мануалы настоящие!
MECHANISM TROUBLESHOOTING GUIDE
E.
In PB mode Tape Presence not sensed.
Is the Pinch Roller attached to the Capstan Motor Shaft?
NO
Check Alignment positions (page 4-14)
YES
Does the T/Up Reel turn?
NO
Is the Belt ok?
NO
Replace the Belt.
YES
Does the Capstan Motor turn?
YES
Check the clutch and the Idler Assembly.
YES
Does the Drum Motor turn?
NO
Is the Voltage supplied to the Capstan Motor Vcc1,Vcc2 each?
YES
Are there DPG, DFG Pulses?
YES
Is the terminal voltage of Capstan Motor supplied more than 4V?
NO
Check Servo, Power.
YES
Are the T/Up Supply Reel Sensors ok?
YES
Replace the Capstan Motor.
YES NO
Check Servo, Syscon. Is the Vcc voltage of the Drum Motor normal?
NO
Check Syscon, Circuit.
YES
Is the terminal voltage of the Drum Motor more than 2.3V?
NO
Check Syscon, Circuit.
YES
Replace the Drum Motor.
4-25
|
|
 |
> |
|