Who's Online
There currently are 5831 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
;
Exactly as described, a Service Manual complete with the schematics and PCB layout delivered in a timely manner. Many thanks for the great service.
;
some of the writing is a bit blur but the part in the schmatic was great and i have fixed the machine thanks
;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
D
Voreinstellungen / Abgleichhinweise
GB
Pre-adjustments / alignment instructions
Ausstattung des Arbeitsplatzes
Netzgerät 12 V regelbar, 10 A Me�sender (z.B. Meguro, Leader, Kenwood) Hochohmiges Voltmeter Ri > 10 M� Outputmeter; Frequenzzähler; NF-Millivoltmeter; Stereocoder Oszilloskop: - Empfindlichkeit: 5 mV bis 50 Volt/cm. - Bandbreite: Gleichspannung bis 50 MHz. - Tastköpfe 10:1 und 1:1 - Schraubendreher / Abgleichstifte (keramisch) - Lötstation -
Workbench equipment
Power adapter 12 volts adjustable, 10 A Signal generator (Meguro, Leader, Kenwood) High impedance voltmeter Ri > 10 M� Output meter; frequency counter; AF millivoltmeter; stereo encoder Oscilloscope: - inp. sensitivity: 5 mV to 50 volts per division - bandwidth: d.c. to 50 MHz - Probes 10:1 and 1:1 - Screwdriver / alignment pins (ceramic) - Soldering station
Vorbereitende Arbeiten
Bevor Sie den elektrischen Abgleich durchführen, müssen Sie Sharx ausschalten: 1. Drücken Sie die Taste "MENU". 2. Betätigen Sie die Taste oder bis im Display "SHARX" angezeigt wird. 3. Drücken Sie die Taste < oder > bis im Display "NO SHARX " erscheint.
Preparatory steps
Switch off Sharx before performing the electrical alignment:
1. Press the "MENU" key. 2. Press the key or until �"SHARX"appears in the display. 3. Press < or > until "NO SHARX " appears in the display.
Lautsprecheranschlu� Der Lautsprecherausgang mu� mit 4 � abgeschlossen sein.
Loudspeaker connections The loudspeaker output must be terminated with 4 �.
Abgleichhinweise
Wellenbereich: FM = 87,5 MHz - 108 MHz (100 kHz automatische Suchlaufschritte) (50 kHz manuelle Suchlaufschritte)
Notes on alignment
Wavebands: FM = 87.5 MHz - 108 MHz (100 kHz automatic tuning steps) (50 kHz manual tuning steps)
MW = 531 kHz - 1602 kHz (9 kHz automatische Suchlaufschritte) (9 kHz manuelle Suchlaufschritte) LW = 153 kHz - 279 kHz (9 kHz automatische Suchlaufschritte) (1 kHz manuelle Suchlaufschritte)
MW = 531 kHz - 1602 kHz (9 kHz automatic tuning steps) (9 kHz manual tuning steps) LW = 153 kHz - 279 kHz (9 kHz automatic tuning steps) (1 kHz manual tuning steps)
AM + FM - Abgleich - Den AM- und FM-Abgleich müssen Sie durchführen, wenn bei einer Reparatur frequenzbestimmende Bauteile ausgetauscht oder verstellt wurden. - Nach Reparatur- bzw. Abgleicharbeiten müssen die Geräteparameter neu programmiert werden. Für den Abgleich müssen Sie die Stationstasten mit folgenden Frequenzen programmieren: Taste FM1 MHz MW kHz 1 97,1 900 2 3 4 5 6
AM + FM alignment - The AM and FM alignment has to be carried out if components that determine the circuit's frequency have been replaced or distuned. - After a repair or alignment job make sure to reprogram the basic product parameters. For the alignment you must store the following frequencies on the station presets : Preset FM1 MHz MW kHz 1 97.1 900 2 3 4 5 6
Abschirmung Der HF-Abgleich mu� mit Unterdeckel erfolgen.
Radio shielding The RF alignment has to be performed with the bottom cover in place. Required after replacement of D1/D810: - Alignment of front-end and intermediate circuit - Programming the FM reference field strength - Programming the AM reference field strength
Nach dem Auswechseln von D1/D810 erforderlich: - Abgleich des Vor- und Zwischenkreises - Programmierung der Bezugsfeldstärke für FM - Programmierung der Bezugsfeldstärke für AM
-6-
|
|
|
> |
|