This is a good quality scan of the original Service Manual from Nordmende, Germany. Contains the circuit diagram, PCB layout, adjust/tune instructions as well. It is NOT in English but in GERMAN language! That was quite right for my german friend from the lower east side in Berlin.
 ;
Received via e-mail this PDF manual is worth the money. This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand. I have later seen the original manual and it was printed in colour, but this particular manual is black & white but scan resolution is high end quality! All drawings and pictures are presented in great detail. So, nearly perfect score in my opinion.
If you own the turntable you also should own the manual!
Dolby®-Pegeleinstellung
Me�punkte ............................... MP 1377, MP 1378 Signalquelle ............................. Dolby®-Testcassette 400 Hz / 200 nWb/m Abgleichelemente .................... R 1241, R 1261 Spezifikation ............................ 450 mV ± 27 mV 1. Schalten Sie die Dolby®-Funktion aus. 2. Legen Sie die Dolby®-Testcassette in den Cassettenschacht ein, und starten Sie die Wiedergabe. 3. Stellen Sie mit R 1241 einen Pegel von 450 mV ± 27 mV an MP 1277 ein. Stellen Sie mit R 1261 einen Pegel von 450 mV ± 27 mV an MP 1278 ein.
* Rauschunterdrückungssystem unter Lizenz von Dolby Laboratories hergestellt. Das Wort Dolby und das Symbol des doppelten D sind die Markenzeichen von Dolby Laboratories.
Dolby® Adjustment
Measuring points ..................... MP 1377, MP 1378 Signal source ........................... Dolby® test cassette 400 Hz / 200 nWb/m Alignment elements ................. R 1241, R 1261 Specification ............................ 450 mV ± 27 mV 1. Switch Dolby® off. 2. Insert the Dolby® test cassette into the cassette compartment. Start tape play. 3. Use R 1241 to adjust a level of 450 mV ± 27 mV at MP 1277. Use R 1261 to adjust a level of 450 mV ± 27 mV at MP 1278.
* Noise reduction system manufatured under the licence of Dolby Laboratories. The Dolby logo and the double D Dolby symbol are registered trademarks of Dolby Laboratories.
Logik-Platte Logic board
PL 0312 A05
R1261
R1241
6 8 1
1377
4 1
8
1
D1140
9 16
D1250
9 11 16
D1350
5 8
1378
R1261 R1241
- 11 -
|
|
 |
> |
|