Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is the ONLY copy of this manual I could find for a realistic price. Even Panasonic could not provide me with one.
The PDF is a very good copy and it helped me diagnose and find the fault with the unit I have.
 ;
Very complete and well reading drawings. Documentation is essential for successful repairs.Good documentation, with all that is necessary. This manual was what I was waiting with all the information necessary for the repairing I need it for. You must buy it if you want to do repairs or simply understand how it works.
 ;
Excellent service manual includes everything is need to repair this radio-caseete, how to disassemble, wiring diagram, all , waiting time until the download was only a few hours. I'm going to buy service manuals from here, are cheap and very good.Thank you.
 ;
Good service manual,i saved from scrapping this deck,is now fully functional.Thanks.
 ;
Found this to be the manual included with the original packinging, was helpfull but did not give any detailed repair instructions.
ICD-P28
9. USB test � When the menu starts the USB self-check, either presence or absence of the Vbus is judged. (Vbus is present: �VBUS: ON�, Vbus is absent: �VBUS: OFF�) � The USB driver always works regardless of presence or absence of the USB signal only when Vbus is available during the USB test. At this time, turning on HOLD causes the set to move to the suspend state. Turning off the Vbus causes the set to return to the test menu. When Vbus is supplied with the menu displayed, the key will be inoperative. Be sure to press x�B key before supplying.
11. Menu reset � Pressing the x�B key causes the set to enter the menu initialization standby state. � Once all the keys below are input in this condition, the EEPROM will be initialized (The settings in the menu and the user name will be defaulted.). At the same time, the WakeUp signal is checked, too. � Check keys (in any order of their inputs) FOLDER , DIVIDE , DISPLAY , MENU , MIC SENS , ERASE , STOP , REC/STOP , PAUSE , PLAY/STOP (ENTER) , > , . , HOLD on, HOLD off (All is normally ended: �ALLOK�/NG in initialization write to EEPROM: INIT. NG) � Turn the power off in order to exit this mode.
x�B
OFF
VBUS on VBUS
STOP
USB
Cut VBUS
ON RST
x�B
KEY
After input all keys PUSH
VBUS
HOLD ON
MENU
STOP
Cut VBUS
PC
LINK Suspend mode
INIT (Blink)
10. Key durability test � Input of x�B key causes the counter to be �- - - - - -�, entering the test waiting mode. Input of x�B key causes the counter to be �000000�, entering the key durability test mode. In this mode, all key inputs and ON and OFF operations of the slide switch are counted with a count display. Turn the power off in order to exit this mode.
Case of initial setting and reset operated normal end.
Ok
ALL
Key endurance test mode x�B
KEY KEY
x�B
KEY
COUNT
STOP
------
00 00 00 any keys or slid switchs on/off
KEY
00 00 01
10