Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Great tape deck manual!
I'm very positively surprised, because it is a very long manual, lot of pages, drawings, diagrams, description of how to make the alignment and adjustment procedures.
It is as good as the old "Naka" manuals from the 1970's - if somebody have seen them, they know what I mean by that.
I recommend to buy this very much !
 ;
I am a vintage hifi collector. No way to fix that device without the appropriate service manual...thanks to your site I got it and every thing is easier now. I got the manual right after ordering: fast cheap accurate ... thank you
 ;
Wonderful job clear. Qick fantastic. These people are really good. If even a problem arise they are wonderful assisting you. These scheme is so net despite this is a very old TV. Thank you for everything!!!!!!!!
 ;
Detailed schematic diagram, manual for professionals
 ;
Good service manual,exploded view,adjusment and test point locations,head alignment,mechanical checks and adjusments,all perfect.
SECTION 5 ELECTRICAL ADJUSTMENTS
0 dB = 1 µV
[AM (MW/LW)*] * AM : ICF-C470 MW/LW : ICF-C470L Setting: Band switch: AM (MW/LW)
AM RF signal generator Put the lead-wire antenna close to the set. MAIN board TP (SPK +) level meter 8� set + �
AM IF ADJUSTMENT Adjust for a maximum reading on level meter T1 455 kHz AM (MW *2) FREQUENCY COVERAGE ADJUSTMENT Adjust for a maximum reading on level meter L4 CT1-3 520 kHz 1,750 kHz (1,650 kHz *1)
AM (MW *2) TRACKING ADJUSTMENT Adjust for a maximum reading on level meter L1 (L1-1 *2) 600 kHz CT1-4 1,400 kHz
30% amplitude MAIN board TP (SPK �) modulation by 400 Hz signal Output level: as low as possible
LW FREQUENCY COVERAGE ADJUSTMENT *2 Adjust for a maximum reading on level meter CT6 145 kHz
[FM] Setting: Band switch: FM
FM RF signal generator 0.01 µF set 22.5 kHz frequency deviation by 400 Hz signal Output level: as low as possible MAIN board TP (FM ANT) MAIN board TP (SPK +) level meter 8� + � MAIN board TP (SPK �)
LW TRACKING ADJUSTMENT *2 Adjust for a maximum reading on level meter L1-2 CT5 160 kHz 240 kHz
FM FREQUENCY COVERAGE ADJUSTMENT Adjust for a maximum reading on level meter L2 86.5 MHz CT1-1 109.5 MHz
� Repeat the procedures in each adjustment several times, and the frequency coverage and tracking adjustments should be finally done by the trimmer capacitors. � Remove FM antenna in FM adjustments. Adjustment Location: Main Board (See page 8)
FM TRACKING ADJUSTMENT Adjust for a maximum reading on level meter CT1-2 109.5 MHz *1) Except US, Canadian models *2) ICF-C470L
�7�
|
|
 |
> |
|