Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Complete and very useful. Could have benefited from a little higher resolution on the schematic and layout diagrams for improved legibility.
 ;
Great Service Manual, Very Complete, as advertised, Perfect, Thanks!
 ;
Good quality service manual.It has helped me to fix my FV1800,particularly for replacing the dial cord.The scheme is on A3 format and very readable.Thank.Olivier.
 ;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
 ;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
SECTION 3 ELECTRICAL ADJUSTMENTS
0dB=1 µV [FM/TV Section] Setting: BAND switch: FM1 or TV
FM RF SSG 0.01µF set level meter + �
FM FREQUENCY COVERAGE ADJUSTMENT L8 Confirm Adjust for a reading on digital voltmeter. 87.5 MHz (TV 2 ch) 2.3 ± 0.1 V (1.0 ± 0.1 V) 108.0 MHz 8.5 ± 0.5 V (12.5 ± 0.5 V)
Adjustment and Connection Location:
Note: Not use the FM RF signal generator in this adjustment.
[MAIN BOARD] (Component Side)
(
): ICF-S79V
T2 AM IF FM antenna ground (JW17) T1 TV IF (ICF-S79V only) L8 FM FREQUENCY COVERAGE L6 CT4
IC2
FM TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L6 CT4 87.5 MHz (TV 2 ch (59.75 MHz)) 108.0 MHz
± 22.5 kHz frequency speaker terminal deviation by 400 Hz FM lead wire antenna terminal signal Output level: as low as possible
( ICF-S79L only
): ICF-S79V
[AM (LW/MW) Section] Setting: BAND switch: AM (MW) or LW
Put the lead-wire antenna close to AM RF SSG the set. set 30% amplitude speaker terminal modulation by 400 Hz signal Output level: as low as possible
LW FREQUENCY COVERAGE ADJUSTMENT Adjust for a reading on digital voltmeter. CT5 153 kHz 2.3 ± 0.1 V Confirm 279 kHz 8.5 ± 0.5 V Note: Not use the AM RF signal generator in this adjustment.
L2 TV FREQUENCY COVERAGE (ICF-S79V only) CT1
IC1
level meter + �
ICF-S79L only
LW TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L5 (LW side) CT2 162 kHz 243 kHz
FM TRACKING
L1
TV TRACKING (ICF-S79V only) FM/TV
L9 AM (MW) FREQUENCY COVERAGE
MW L5 LW
antenna input (JW18)
digital voltmeter MAIN board TP (VT) + �
AM (MW) FREQUENCY COVERAGE ADJUSTMENT Adjust for a reading on digital voltmeter. L9 531 kHz (530 kHz) 2.8 ± 0.1 V
CT5 LW FREQUENCY COVERAGE (ICF-S79L only) L5 CT3
TV antenna ground (JW20)
Repeat the procedures in each adjustment several times, and the frequency coverage and tracking adjustments should be finally done by the trimmer capacitors.
Confirm 1,602 kHz (1,710 kHz) 9.5 ± 0.5 V Note: Not use the AM RF signal generator in this adjustment.
(
AM (MW) TRACKING ADJUSTMENT
): ICF-S79V
AM (MW) TRACKING CT2 L5
ICF-S79V only
TV FREQUENCY COVERAGE ADJUSTMENT Adjust for a reading on digital voltmeter. L2 WEATHER 2 ch 1.0 ± 0.1 V Confirm TV 13 ch 10 ± 0.5 V Note: Not use the FM RF signal generator in this adjustment.
Adjust for a maximum reading on level meter. L5 <MW side> CT3 621 kHz (590 kHz) 1,395 kHz (1,490 kHz)
LW TRACKING (ICF-S79L only)
< (
AM IF ADJUSTMENT
>: ICF-S79L ): ICF-S79V [MAIN BOARD] (Conductor Side)
ICF-S79V only
TV TRACKING ADJUSTMENT Adjust for a maximum reading on level meter. L1 CT1 WEATHER 2 ch (162.40 MHz) TV 13 ch (215.75 MHz)
Adjust for a maximum reading on level meter. T2 455 kHz
ICF-S79V only
TV IF ADJUSTMENT Adjust for a maximum reading on level meter. T1 10.7 MHz
TP (VT)