|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Found the quality of the copy excellent and a very quick service. I would certainly recommend the service.
 ;
Good quality, clear diagrams. Exactly what I needed.
 ;
Good product. All the information is invcluded, but due to the complexity of the amplifier, it still is difficult to get it to operation again.
 ;
Very professional seller; very fast, accurate and rielable service.
 ;
great works fine, got the manual on mail within a day
INC
JAA79651-R.3695.A (4) Rear lens group alignment â� Mount the lens on the equipment (for center). [ref. â� of (2) for how to fit in it.] â�¡ Set the lens to WIDE-end. Put the zoom-fixing base, and rotate the zoom ring towards TELE until the lens touches the zoom-fixing base.
Zoom ring Zoom-fixing base
�� Adjust the cross lines by rotating the "LIGHT CONT." knob of "MEGALIGHT 100" and rotating the focus
ring from "infinity"-end so that the calibration of the cross lines can be seen clearly.
X-axis
Y-axis
Focus ring
Cross lines Note) In case the cross lines are tilted, adjust Light cont. knob them by turning the chart, which is screwed in the rear tube of the equipment.
�� Unlock the holder-moving lever, and move the holder down slowly by the lever. Caution: Move the holder down so that a load is not put on the lens body. Also, adjust so that the cross lines remain unmoving, when the knobs of the micrometer (X and Y axes) are rotated and the holder is moved up and down.
- A56 ・ AF-S DX 18-135/3.5-5.6G -
|
|
 |
> |
|