Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
 ;
The manual was well-scanned and easy to read. As an added bonus, the Operator's Manual was bundled with the Service Manual!
I'd definitely use owner-manuals.com again.
 ;
Finally, i found one website, where i can download this service manual , and fix my hifi. The service manual is very good, and easy to download and to print.
KDC-716S/8018
ADJUSTMENT
Test Mode
1. How to enter test mode While holding the FM key and the Preset 6 key, reset the unit. 2. How to exit from test mode. While holding down the Preset 6 key, reset the unit. Note: Does not exit from test mode ACC-OFF, Power-OFF or Momentary power down 3. Test mode reset status � Sources are all OFF � All display segment lit up � Volume at -10dB (shows 30 on display) � LOUD is OFF. � CRSC is OFF regardless of whether switching function is provided. � SYSTEM Q is in FLAT � Blank skip is OFF. (C/R model) � LEDs are white, no scanning. (VLCD model) 4. Special displays in Tuner When the following displays appear in tuner mode it shows a problem with the front end. � �TNE2P NG� ..... F/E is not aligned and EEPROM is in reset (no settings) such as when shipped. � �TNCON NG� .... Cannot communicate with F/E (front end). 5. K3I switching Each time the Preset 6 key is pressed in Tuner mode, switches one at a time through the following sequence: AUTO � Forced Wide � Forced Middle � Forced Narrow � AUTO. When reset, displays the following in AUTO. � AUTO ................ FMA � Forced Wide ..... FMW � Forced Middle ... FMM � Forced Narrow .. FMN 6. CD receiver test mode specifications � No automatic ejection during reset-start. Does not make a CD check in reset with a CD loaded. � Using the Track up key jumps to the following tracks. No.9�No.15�No.10�No.11�No.12�No.13�No.14�and back to No. 9 � Using the Track down key moves 1 track downwards from the track being played. 7. Audio items � Momentarily pressing the Q key calls up audio adjustment mode. � Pressing the � key on the remote control calls up audio alignment mode. � Continuous forward is disabled on the remote control. � Bass/Middle/Treble are settable in 3 steps of MIN/ CENTER/MAX with the Track up/down keys.
PRESET5 PRESET2 PRESET3
� Balance is settable in 3 steps of Left MAX/CENTER/Right MAX with the Track up/down keys. � Fader is settable in 3 steps of Rear MAX/CENTER/Front MAX with the Track up/down keys. � HPF is settable in 2 steps of THRU/220Hz with the Track up/down keys. � LPF is settable in 2 steps of THRU/120Hz with the Track up/down keys. � Bass f/Bass Q/Bass EXT/Middle f/Middle Q/Treble f do not appear in the audio alignment. 8. Menu items � Momentarily pressing the CLK key calls up the Menu mode. � The DNPP/SBF keys on the remote control calls up Menu mode. � Continuous forward is disabled on the remote control. � Calendar adjust, calendar display switching and calendar memo are eliminated from forward (FL model) � In color alignment mode, Preset 1 is red, 2 is blue, 3 is green and 4 is white. (VLCD model). � Contrast is set in 3 steps of 0, 5, 10 and the reset value is 5. (VLCD/LCD models) � Brightness adjustment is set in 3 steps of 0, 5, 10 and the reset value is 10. (Normal FL model) 9. Backup current measurement The MUTE terminal turns off 2 seconds (not 15 seconds) after being reset in ACC off (backup on). (The panel, CD and tape mechanisms are disabled during this time.) 10. Special displays during All-Off with all lamps on The following displays appear when the preset keys are pressed with all display segment lit up.
PRESET1 Version display (8 digits; Mo. Dy. Hr. Mn.) (Display) SYS XXXXXXXX system microprocessor PAN XXXXXXXX panel microprocessor Serial No. display (8 digits) Note: CD/RK type eXcelon model (Display) SNo XXXXXXXX Press once: Power-on time display (Does not count during All-Off) Press long: Clears the time display during power-on. PRESET4 (Display) PonTim XXXXX (C/R) MAX 65535(time) Press once: TAPE/CD/MD operating time display. Press long: Clears TAPE/CD/MD operating time. (Display) CDTime XXXXX (CD/R) TapTim XXXXX (C/R) MAX 65535(time) Press once: TAPE/CD/MD eject count display. Press long: Clears TAPE/CD/MD eject count display. (Display) EjeTim XXXXX PRESET6 MAX 65535(count) Press once: PANEL open/shut count display. Press long: Clears PANEL open/shut count display. (Display) PnCnt XXXXX MAX 655350(count)