Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
 ;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
 ;
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
 ;
Very good manual, at a very good price. Received in a timely manner
 ;
Only thу cover has poor quality, internal material has excellent quality - exactly what I needed
Thanks!
KDC-715S/8015/8016
TEST MODE
13. Simplified method for clearing the security code (Only for type K) (1) When code is requested, continue pressing VOL UP key for three seconds while pressing the DISP key. (--- disappear.) (2) Input "KCAR," using the remote controller (the same as the 98 Model) � Press Tenkey 5 twice and then press track-up key. (Inputting "K") � Press Tenkey 2 three times and then press trackup key. (Inputting "C") � Press Tenkey 2 once and then press track-up key. (Inputting "A") � Press Tenkey 7 twice and then press track-up key. (Inputting "R") (3) Then, the security is released and the unit goes into the Tuner Mode. 14. Writing MASK KEY on line (E2PROM in initial condition) (1) While pressing the FM key and Preset 6 key, press reset key to enter the test mode. (2) Press AUDIO key for full one second to put the unit into the menu mode. (3) Select the "MASK KEY," using the FM key or AM key. (4) Press on the track up/down key to display "TRANSMIT 1." (5) Point the MASK KEY to the light receptor and press it for 0.5 second or longer. (6) When "TRANSMIT 2" is displayed, press MASK KEY for 0.5 second or longer. When this is conducted, the counter codes for the first time and the second time will not be compared. (7) When "APPROVED" is displayed, writing is completed. time the demonstration mode is set and the test mode is released. Note: After an elapse of 30-minute period, during which no code is written, an error is effected and the device will power off. 15. Releasing MASK KEY requests (When reset or backup is off when MASK KEY is approved) (1) When power is turned on, "TRANSMIT 1" is displayed and the unit goes into MASK KEY request mode. (2) Point the MASK KEY to the light receptor and press it for more than 3 seconds (until the level display indicates full) (3) When "TRANSMIT 2" is displayed, press the MASK KEY again for more than three seconds. At this point, when "TRANSMIT 1" is displayed, repeat the process in (2) above for the second time. (4) When "APPROVED" is displayed, MASK KEY is approved and the unit turns power on. 17. Clearing from the MASK KEY (1) While pressing FM key and Preset 6 key at the same time, press RESET to enter the test mode. (2) Press the AUDIO key for full one second to put the unit into the menu mode. (3) Select MASK KEY, using track up/down key. (4) Press on the FM key or AM key for full two seconds and the unit will display "TRANSMIT 1." (5) Point the MASK KEY release controller to the light receptor and press it for 3 seconds or longer. (Until the level display indicates full.) (6) When "TRANSMIT 2" is displayed, press MASK KEY for 3 seconds or longer for the second time. If "TRANSMIT 1" is displayed, start again from (5) above. (7) When "APPROVED" is displayed, E2PROM is cleared. The unit goes back to the condition described in Line 14: Writing MASK KEY on line (E2PROM in initial condition) 18. Other � Automatic panel closing does not occur in case a TAPE, CD, or MD is inserted. � Panel is opened/closed when ATT key is turned On/Off. ( A remote controller is used when turning ATT on.) � The DNPP/SBF key of the remote controller (RC-510) is used for tuning the menu mode On/Off. � The OPEN/CLOSE key of the remote controller (RC510) is used for tuning the audio mode On/Off. � The feed on the menu will be feeds only for necessary features. � "CODE OFF" and other displays will not be issued when the power is turned on. � The dimmer of the FL model and contrast on the LCD model can be adjusted only for 0/5/10 by the UP/ DOWN key. 16. Initializing MASK KEY (returning to the default condition from MASK KEY approved state) (1) While pressing the FM key and Preset 6 key at the same time, press RESET to enter the test mode. (2) "TRANSMIT 1" is displayed and the unit goes into MASK KEY request mode. The display at this point will be "**" instead of "[ ]". (3) Use MASK KEY release remote controller for more than three seconds. (4) When "TRANSMIT 2" is displayed, press the MASK KEY for more than three seconds for the second time. (5) When "APPROVED" is displayed, the MASK KEY is released and the demonstration mode is set. Then, the test mode is released, returning the unit into default condition.