More than pleased with my prurchase, very good product for the price.
 ;
Manual-link came 30 minutes after having paid for an extremely rare (40 years old) item (sony icr-120) and helped me to get the radio rework again. So really good help for me, fast and reliable delivery and -taken that into consideration- a very reasonable price for that service. So thanks again! Mike, Germany
 ;
Some of the pictures in this manual are a bit irritating. I had to dissassemble the unit and some of the screws have different threads, which is not mentioned in this manual. Also some of the drawings of the boards look different than the actual boards.
After all, the manual was very useful. I was able to recalibrate the capstan drive and it is working fine again.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
KDC-8021/M9021/X859
TEST MODE
Security items
1. Forced power-ON mode (all models) Even when writing is permitted by the security function (mask key), Power-on can be set for a 30 minute period each time the reset key is pressed while holding down the Q key and [4/8] keys. After 30 minutes elapses, can only be restored by using reset. 2. How to register the security code for EEPROM (F/E) replacement (coded security models) (1) Enter the test mode. (See "1. How to enter the test mode") (2) Press the [4/8] key to enter the MENU MODE. (3) While "Security" is displayed, press and hold the Track up or down key for a second to enter the security registration mode. (4) Enter the code using the FM/AM/Track up/Track down keys. FM key: Increments the number. AM key: Decrements the number. Track up key: Moves the cursor to the right. Track down key: Moves the cursor to the left. (5) Hold down the Track up key for at least 3 seconds and the message, "RE-ENTER" appears, so once again enter the code according to Step 4 above. (6) Hold down the Track up key for at least 3 seconds, and the message, "APPROVED" appears. (7) Cancel test mode. (See, 2. How to cancel the test mode.) Note: All clear cannot be performed on the security code for this model. 3. Simple way to clear the security code (K type only) (1) During code request mode, press the Track Up key for at least 3 seconds while holding down the AUTO key. (---- will disappear) (2) Enter, "KCAR" with the remote controller as described below. (Same as on 01 model.) � Press the remote controller 5 key twice, and press the Track Up key. (Enters a "K") � Press the remote controller 2 key three times, and press the Track Up key. (Enters a "C") � Press the remote controller 2 key once, and press the Track Up key. (Enters an "A") � Press the remote controller 7 key twice, and press the Track Up key. (Enters an "R") (3) Security function is canceled and unit sets to All-Off mode. (4) Code request mode appears if a mistake was made in entering the numbers. 4. Method of writing the Mask key while the EEPROM is in the initial status (1) Enter the test mode. (See "1. How to enter the test mode") (2) Press the [4/8] key to enter the Mask key registration mode. "TRANSMIT1" should be displayed now. The display at this time should show "< >" in place of "[ ]". (3) Point the Mask key remote toward the light sensor, and press and hold its key for more than 0.5 second. (4) When "TRANSMIT2" is displayed, press and hold the key on the Mask key remote for more than 0.5 second again. The first and second counter codes are not compared at this time. (5) When "APPROVED" is displayed, the write operation is complete. Now the demonstration mode is initiated and the test mode is terminated. (Note) In the same way as previous models, if 30 minutes have elapsed with no code written, an error occurs and the power is turned OFF. 5. Method of initializing the Mask key (How to reset the unit from the Mask key approved condition to the factory condition) (1) Enter the test mode. (See "1. How to enter the test mode") (2) "TRANSMIT1" is displayed and the Mask key entry request mode is initiated. The display at this time should show "� �" in place of "[ ]". (3) Press and hold the key on the Master key remote for more than 3 seconds. (4) When "TRANSMIT2" is displayed, press and hold the key on the Master key remote for more than 3 seconds again. (5) When "APPROVED" is displayed, the Mask key is cleared, the demonstration mode is initiated, the test mode is terminated and the unit returns to the factory condition. 6. Method of clearing all Mask key-related data (1) Enter the test mode. (See "1. How to enter the test mode") (2) Press the [4/8] key to enter the Mask key registration mode. "TRANSMIT1" should be displayed now. (3) Point the Master key remote toward the light sensor, and press and hold its key for more than 3 seconds (until the level display shows the full condition). (4) When "TRANSMIT2" is displayed, hold the key on the Mask key remote for more than 3 seconds again. If " TRANSMIT1 "is displayed in place of" TRANSMIT2 ", restart the procedure from step 3. (5) When "APPROVED" is displayed, all security data is cleared and the unit returns to the condition before Mask key writing with the EEPROM in the initial status
12
|
|
 |
> |
|