|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
a solid deal - quick and without any problems.
I life in europe - with downloads no loosing time
once again
 ;
got exactly what i ordered in a very timely manner. will use again for other manuals
 ;
I'm happy. Good quality. Very helped me with my work..............................
 ;
This is the second Manual I have ordered from owner-manuals, I give it five stars because it is exactly what I expected given the age of the equipment. So the contents look a bit aged and the pictures a bit grainy, it fulfills my needs and I am glad I can still get hold of them.
 ;
thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
KDC-8021/M9021/X859
TEST MODE
Security items
1. Forced power-ON mode (all models) Even when writing is permitted by the security function (mask key), Power-on can be set for a 30 minute period each time the reset key is pressed while holding down the Q key and [4/8] keys. After 30 minutes elapses, can only be restored by using reset. 2. How to register the security code for EEPROM (F/E) replacement (coded security models) (1) Enter the test mode. (See "1. How to enter the test mode") (2) Press the [4/8] key to enter the MENU MODE. (3) While "Security" is displayed, press and hold the Track up or down key for a second to enter the security registration mode. (4) Enter the code using the FM/AM/Track up/Track down keys. FM key: Increments the number. AM key: Decrements the number. Track up key: Moves the cursor to the right. Track down key: Moves the cursor to the left. (5) Hold down the Track up key for at least 3 seconds and the message, "RE-ENTER" appears, so once again enter the code according to Step 4 above. (6) Hold down the Track up key for at least 3 seconds, and the message, "APPROVED" appears. (7) Cancel test mode. (See, 2. How to cancel the test mode.) Note: All clear cannot be performed on the security code for this model. 3. Simple way to clear the security code (K type only) (1) During code request mode, press the Track Up key for at least 3 seconds while holding down the AUTO key. (---- will disappear) (2) Enter, "KCAR" with the remote controller as described below. (Same as on 01 model.) � Press the remote controller 5 key twice, and press the Track Up key. (Enters a "K") � Press the remote controller 2 key three times, and press the Track Up key. (Enters a "C") � Press the remote controller 2 key once, and press the Track Up key. (Enters an "A") � Press the remote controller 7 key twice, and press the Track Up key. (Enters an "R") (3) Security function is canceled and unit sets to All-Off mode. (4) Code request mode appears if a mistake was made in entering the numbers. 4. Method of writing the Mask key while the EEPROM is in the initial status (1) Enter the test mode. (See "1. How to enter the test mode") (2) Press the [4/8] key to enter the Mask key registration mode. "TRANSMIT1" should be displayed now. The display at this time should show "< >" in place of "[ ]". (3) Point the Mask key remote toward the light sensor, and press and hold its key for more than 0.5 second. (4) When "TRANSMIT2" is displayed, press and hold the key on the Mask key remote for more than 0.5 second again. The first and second counter codes are not compared at this time. (5) When "APPROVED" is displayed, the write operation is complete. Now the demonstration mode is initiated and the test mode is terminated. (Note) In the same way as previous models, if 30 minutes have elapsed with no code written, an error occurs and the power is turned OFF. 5. Method of initializing the Mask key (How to reset the unit from the Mask key approved condition to the factory condition) (1) Enter the test mode. (See "1. How to enter the test mode") (2) "TRANSMIT1" is displayed and the Mask key entry request mode is initiated. The display at this time should show "� �" in place of "[ ]". (3) Press and hold the key on the Master key remote for more than 3 seconds. (4) When "TRANSMIT2" is displayed, press and hold the key on the Master key remote for more than 3 seconds again. (5) When "APPROVED" is displayed, the Mask key is cleared, the demonstration mode is initiated, the test mode is terminated and the unit returns to the factory condition. 6. Method of clearing all Mask key-related data (1) Enter the test mode. (See "1. How to enter the test mode") (2) Press the [4/8] key to enter the Mask key registration mode. "TRANSMIT1" should be displayed now. (3) Point the Master key remote toward the light sensor, and press and hold its key for more than 3 seconds (until the level display shows the full condition). (4) When "TRANSMIT2" is displayed, hold the key on the Mask key remote for more than 3 seconds again. If " TRANSMIT1 "is displayed in place of" TRANSMIT2 ", restart the procedure from step 3. (5) When "APPROVED" is displayed, all security data is cleared and the unit returns to the condition before Mask key writing with the EEPROM in the initial status
12
|
|
 |
> |
|