Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Categories
Information
Featured Product
Home >> KENWOOD >> KDCM907 Service Manual
 
 0 item(s) in your cart 

KENWOOD KDCM907
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of KENWOOD KDCM907 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
5 of 5 Stars! KDCM907 KENWOOD Service Manual by Endre Kajari;
Perfect, complete manual, exactly what I needed. Recommended to everyone.
Other Reviews
 CDP1100 TEAC Service Manual by Antony Pessoa;
This manual is very useful because it presents the technical specifications of the cd player, including the manufacturer of the reader, this helps if you need to replace it. It also displays the settings and layout of the circuit.
 EWV404 FUNAI Service Manual by Lou Hurrle;
Manual was a good representation of service infomation for the EWV404. It worked well for my repair.
 CS-R10 AIWA Service Manual by Viktor Strogan;
Great quality copy, right what I was looking for, all I need to fix my radio. Thanks
 SM-152 INFINITY Service Manual by LUIS CUEVA;
I BOUGHT A PAIR OF INFINITY VINTAGE SPEAKERS THAT REQUIRED TO BE REPAIRED AND THE ELECTRONIC TECHNICIAN ASKED ME FOR THE SERVICE MANUAL. I TRIED TO GET IT AT THE MANUFACTURER'S SITE WITH NO SUCCESS, SO I STARTED TO LOOK FOR IT IN THE WEB FOR A LONG TIME, UNTIL I FOUND THE SERVICE MANUAL IN THIS EXCELLENT SITE "OWNER'S MANUAL.COM". NOW I HAVE MY SPEAKERS WORKING AND ENJOYING THE MUSIC I LIKE. THANKS TO "OWNER`S MANUAL.COM" I RECOMMEND THIS SITE TO EVERYONE.
 3537 ALPINE Service Manual by Jozef Benedik;
Very quick response. Very good and accurate print quality of the scanned document.

Text excerpt from page 3 (click to view)
KDC-M907
TEST MODE
� Panel open and closes with press long the [Q] key. � No displays such as �CODE OFF� during Power-ON. � Pressing the [TI (AUTO)] key during changer operation turns on 2 zone. Cancel by pressing the [TI (AUTO)] key again. The P/S dot is lit during 2 zone. � Pressing the [4/8] key for 1 second or more during All OFF, calls up the Mask Key (security) write mode. 3) Security function is canceled and unit sets to All-Off mode. 4) Code request mode appears if a mistake was made in entering the numbers. 4. Method of writing the Mask key while the EEPROM is in the initial status 1) Enter the test mode. (See 1. How to enter the test mode) 2) Press the [4/8] key to enter the Mask key registration mode. �TRANSMIT1� should be displayed now. The display at this time should show �< >� in place of �[ ]�. 3) Point the Mask key remote toward the light sensor, and press and hold its key for more than 0.5 second. 4) When �TRANSMIT2� is displayed, press and hold the key on the Mask key remote for more than 0.5 second again. The first and second counter codes are not compared at this time. 5) When �APPROVED� is displayed, the write operation is complete. Now the demonstration mode is initiated and the test mode is terminated. Note : In the same way as previous models, if 30 minutes have elapsed with no code written, an error occurs and the power is turned OFF. 5. Method of initializing the Mask key (How to reset the unit from the Mask key approved condition to the factory condition) 1) Enter the test mode. (See 1. How to enter the test mode) 2) �TRANSMIT1� is displayed and the Mask key entry request mode is initiated. The display at this time should show ���� in place of �[ ]�. 3) Press and hold the key on the Master key remote for more than 3 seconds. 4) When �TRANSMIT2� is displayed, press and hold the key on the Master key remote for more than 3 seconds again. 5) When �APPROVED� is displayed, the Mask key is cleared, the demonstration mode is initiated, the test mode is terminated and the unit returns to the factory condition. 6. Method of clearing all Mask key-related data 1) Enter the test mode. (See 1. How to enter the test mode) 2) Press the [4/8] key to enter the Mask key registration mode. �TRANSMIT1� should be displayed now. 3) Point the Master key remote toward the light sensor, and press and hold its key for more than 3 seconds (until the level display shows the full condition). 4) When �TRANSMIT2� is displayed, hold the key on the Mask key remote for more than 3 seconds again. If �TRANSMIT1� is displayed in place of �TRANSMIT2�, restart the procedure from step 3). 5) When �APPROVED� is displayed, all security data is cleared and the unit returns to the condition before Mask key writing with the EEPROM in the initial status.

Security Items
1. Forced power-ON mode (all models) Even when writing is permitted by the security function (mask key), Power-on can be set for a 30 minute period each time the reset key is pressed while holding down the [Q] key and [4/8] keys. After 30 minutes elapses, can only be restored by using reset. 2. How to register the security code for EEPROM (F/E) replacement (coded security models) 1) Enter the test mode. (See 1. How to enter the test mode) 2) Press the [4/8] key to enter the MENU MODE. 3) While �Security� is displayed, press and hold the [Track up or down] key for a second to enter the secu-rity registration mode. 4) Enter the code using the [FM/AM/Track up/Track down] keys. FM key : Increments the number. AM key : Decrements the number. Track up key : Moves the cursor to the right. Track down key : Moves the cursor to the left. 5) Hold down the [Track up] key for at least 3 seconds and the message, �RE-ENTER� appears, so once again enter the code according to Step 4) above. 6) Hold down the [Track up] key for at least 3 seconds, and the message, �APPROVED� appears. 7) Cancel test mode. (See, 2. How to exit from the test mode.) Note : All clear cannot be performed on the security code for this model. 3. Simple way to clear the security code (K type only) 1) During code request mode, press the [Track up] key for at least 3 seconds while holding down the [AUTO] key. (---will disappear) 2) Enter, �KCAR� with the remote controller as described below. (Same as on 01 model.) � Press the remote controller [5] key twice, and press the [Track up] key. (Enters a �K�) � Press the remote controller [2] key three times, and press the [Track up] key. (Enters a �C�) � Press the remote controller [2] key once and press the [Track up] key. (Enters an �A�) � Press the remote controller [7] key twice, and press the [Track up] key. (Enters an �R�)

3

You might also want to buy

$4.99

KDC-M907 KENWOOD
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…
>
Parse Time: 0.684 - Number of Queries: 108 - Query Time: 0.369