Who's Online
There currently are 5673 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
;
Exactly what was needed to assess the product - excellent value and great service
;
A site where discontinualed schematic diagrams and back dated information can be found on discontinued radios tv's and any electronic equipment can be found. Newer manuals either Service and operating manuals. Radio amateurs should find this site a great source for ham radio equipment manuals. I will return to this site should I need information on any electrical equipment. priced easy to download in a PDF format and print pages need to undertake the repair.
;
Quality scan of the original. All the detail necessary to troubleshoot, repair and adjust the unit. I'm sure I will be downloading more manuals in the future as the need arises.
2-2. Calibration Adjustment of A/D Converter and Video Coder
2-2-1. Preparation for adjustment
1. Set [RGB MODE] of the Custom Setup menu in the service mode to [Other]. 2. Set the [Cal Mode] of the AD Converter in the service mode to [ON]. 3. Set the image quality mode to AV professional standard state.
2-2-3. Component AD adjustment
1. Input All white 90 IRE signal of 1080/60i to the component input terminal. 2. Adjust the Sub Contrast (YUV), that is, adjust the detection value of G to the set value. Detection set value: 230 ± 3 3. Set the component input signal to All gray 20 IRE signal of 1080/60i . 4. Adjust the Sub Bright (YUV), that is, adjust the detection value of G to the set value. Detection set value: 51 ± 3 5. Adjust the CB Offset (YUV), that is, adjust so that the detection value of B is the same as that of G. 6. Adjust the CR Offset (YUV), that is, adjust so that the detection value of R is the same as that of G. 7. Repeat steps 4 to 6 until the detection set value in step 4 is obtained. 8. Repeat steps 2 to 7 until the detection set value in steps 2 and 4 are obtained.
2-2-2. RGB AD adjustment
1. Input All white 90 IRE signal of VGA (640x480/60Hz) to the RGB input terminal. 2. Select RGB Calibration from the AD Converter menu, then adjust the R gain and the B gain in the menu and balance so that the detection values of R and B approximate to the detection value of G. 3. Adjust the Sub Contrast (RGB), that is, adjust the detection values of R, G, and B to the set value. Detection set value: 230 ± 3 4. Set the RGB input signal to All gray 20 IRE signal of VGA (640x480/ 60Hz). 5. Adjust the RGB Bias, that is, adjust the detection values of R, G, and B to the set value. Detection set value: 51 ± 3 6. Repeat steps 1 to 5 described above until the detection set value is obtained.
KE-32TS2U(UC)
2-2
|
|
|
> |
|