This PDF is very comprehensive. It includes drawings, parts lists, schematics, pictures, PCB drawings, mechanical layouts, etc. for all three stackable equipment. The scans are good too. Easy to read and no smudges or black lines. I have no complaints. I will make this site my first stop for finding my service manuals.
DISASSEMBLY AND ASSEMBLY
6. To remove high voltage capacitor. (1) Remove a screw which secure the grounding ring terminal of the H.V.diode and the capacitor holder. (2) Remove the H.V. diode from the capacitor holder. (3) Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron. (1) Remove a screw which secure the magnetron. (2) Remove the magnetron. (3) Reverse the above steps for reassembly.
CAUTION
N ever install the m agnetron w ithout the m etallic gasket plate w hich is packed w ith each m agnetron to prevent m icrow ave leakage. W henever repair w ork is carried out on m agnetron, check the m icrow ave leakage. It shall not exceed 4m W /cm 2 for a fully assem bled oven with door norm ally closed.
|
|
 |
> |
|