INTERLOCK MECHANISM AND ADJUSTMENT
The door lock mechanism is a device which has been specially designed to completely eliminate microwave radiation when the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.
1. Primary interlock switch
When the door is closed, the hook locks the oven door. If the door is not closed properly, the oven will not operate. When the door is closed, the hook pushes the button of the microswitch. Then the button of the primary interlock switch bring it under �ON� condition.
2. Secondary interlock switch and interlock monitor switch
When the door is closed, the hook pushes the lock lever downward. The lock lever presses the button of the interlock monitor switch to bring it under �OFF� condition and presses the button of the secondary interlock switch to bring it under �ON� condition.
ADJUSTMENT
Interlock monitor switch
W hen the door is closed, the interlock m onitor sw itch should be opened before other sw itches are closed. W hen the door is opened, the interlock m onitor sw itch should be closed after other switches are opened.
3. Adjustment steps
(a) Loosen the one mounting screw. (b) Adjust interlock switch assembly position. (c) Make sure that lock lever moves smoothly after adjustment is completed. (d) Tighten completely one mounting screw.
NOTE
M icrow ave em ission test should be perform ed after adjusting interlock m echanism . If the m icrow ave em ission exceed 4m W /cm 2 , readjust interlock m echanism .
|
|
 |
> |
|