Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
as always, rapid and efficient, very good and clear prints
details clearly visible keep going this way!!!!!!
 ;
I expect a wonderful result as alaways!!!!!!
Usually is much faster....
 ;
Wow very wonderful and clear!!!! I will always trust them
 ;
Providing the manual works fine, quickly and without any problems for an acceptable price. After printing the service manual it took me only a short time to repair my carradio from Clarion. Thank You! Greetings from Heiko
 ;
I was searching a way to modify the original phono-in entry (for connection of vynil disc player, with RIAA equalization) to a line-in entry (for connection of modern analog entries, eg. ipod, mp3player).
This service manual gave me the correct hints.
It contains very useful infos for repairing and modifing the hi-fi, such as disassembling instructions, block diagrams, schematic diagrams, PCB prints, replacement parts list.
Very good!
If available, measure current using an accurate leakage current tester. Any reading of 0.35mA or more is excessive and indicates a potential shock hazard which must be corrected before returning the receiver to owner. If a reliable leakage current tester is not available, this allernate method of measurement should be used. Using two clip leads, connect a 1500 Ohm, 10 watt resistor paralleled by a 0.15MF capacitor in series with a known earth ground, such as a water pipe or conduit and the metal part to be checked. Use a VTVM or VOM with 1000 Ohms per Volt, or higher, sensitivity to measure this AC voltage drop across the resistor,. Any reading of 0.35 volt RMS of more is excessive and indicates potential shock hazard which must be corrected before returning he receiver to the owner.
ALIGNMENT PROCEDURES PLEASE READ BEFORE ATTEMPTING SERVICE
1. Use an Isolation Transformer when performing any service on this chassis. 2. Never disconnect any leads while receiver is in operation. 3. Disconnect all power before attempting an repairs. 4. Do not short any position of the circuit while the power is on. 5. For safety reasons, replacing any components should be according with identical replacement parts (SEE PARTS LIST). 6. Before testing, warm up the TV for at least 30 minutes and demagnetize the CRT with an external degaussing coil. 7. When removing a PCB or related component, after unfastening or changing a wire, be sure to put the wire back in its original position. 8. Inferior silicon grease can damage IC�s and transistors. When replacing IC�s and transistors, use only specified silicon grease,. Remove all old silicon when applying new silicon. 9. Before removing the anode cap, discharge eiecticity because it contains high voltage. 10.To adjust MCU N602 installed in the chassis, you should write master slice�s data into this MCU before installing, and no any data except this test manual listed is admitted to be modified without designer�s agree.
Test environment
1. Temperature: 15~35°C 2. Relative humidity: 45 ~ 75% 3. Air pressure: 86 ~ 106kPa
TEST EQUIPMENT
1. DC Power Suply (14V) 2. Oscilloscope 3. High Voltage meter 40KV 4. Multi-meter(internal resistance:DC�20kΩ/V,AC�5kΩ/V) 5. Ammeter(0.5 grade,DC3mA) 6. Degaussing Coil 7. PHILIP Picture Signal Generator(PH5820 or other type)
|
|
 |
> |
|